Back Button PD488588FF Datasheet HTML 50Page - Elpida Memory PD488588FF Datasheet HTML 51Page - Elpida Memory PD488588FF Datasheet HTML 52Page - Elpida Memory PD488588FF Datasheet HTML 53Page - Elpida Memory PD488588FF Datasheet HTML 54Page - Elpida Memory PD488588FF Datasheet HTML 55Page - Elpida Memory PD488588FF Datasheet HTML 56Page - Elpida Memory PD488588FF Datasheet HTML 57Page - Elpida Memory PD488588FF Datasheet HTML 58Page - Elpida Memory Next Button
Zoom Inzoom in Zoom Outzoom out
 54 / 79 page
background image
Data Sheet
E0251N20 (Ver. 2.0)
54
µµµµPD488588FF-C80-40
25. Current and Temperature Control
Figure 25-1 shows an example of a transaction which performs current control calibration. It is necessary to
perform this operation once to every RDRAM in every tCCTRL interval in order to keep the IOL output current in its
proper range.
This example uses four COLX packets with a CAL command. These cause the RDRAM to drive four calibration
packets Q(a0) a time tCAC later. An offset of tRDTOCC must be placed between the Q(a0) packet and read data Q(a1)
from the same device. These calibration packets are driven on the DQA4..3 and DQB4..3 wires. The TSQ bit of the
INIT register is driven on the DQA5 wire during same interval as the calibration packets. The remaining DQA and
DQB wires are not used during these calibration packets. The last COLX packet also contains a SAM command
(concatenated with the CAL command). The RDRAM samples the last calibration packet and adjusts its IOL current
value.
Unlike REF commands, CAL and SAM commands cannot be broadcast. This is because the calibration packets
from different devices would interfere. Therefore, a current control transaction must be sent every tCCTRL /N, where N
is the number of RDRAMs on the Channel. The device field Da of the address a0 in the CAL/SAM command should
be incremented after each transaction.
Figure 25-2 shows an example of a temperature calibration sequence to the RDRAM. This sequence is broadcast
once every tTEMP interval to all the RDRAMs on the Channel. The TCEN and TCAL are ROP commands, and cause
the slew rate of the output drivers to adjust for temperature drift. During the quiet interval tTCQUIET the devices being
calibrated can’t be read, but they can be written.
Figure 25-1 Current Control CAL/SAM Transaction Example
CTM/CFM
DQA8..0
DQB8..0
COL4
..COL0
ROW2
..ROW0
T0
T4
T8
T12
T1
T5
T9
T13
T2
T6
T10
T14
T3
T7
T11
T15 T16
T20
T24
T28
T17
T21
T25
T29
T18
T22
T26
T30
T19
T23
T27
T31 T32
T36
T40
T44
T33
T37
T41
T45
T34
T38
T42
T46
T35
T39
T43
T47
Transaction a0: CAL/SAM
a0 = {Da, Bx}
tCCTRL
Transaction a1: RD
a1 = {Da, Bx}
CAL a0
CAL a2
Q (a0)
tCAC
CAL a0
CAL a0
CAL/SAM a0
Read data from a different
device from an earlier RD
command can be anywhere
prior to the Q(a0) packet.
Read data from a different
device from a later RD
command can be anywhere
after to the Q(a0) packet.
Read data from the same
device from a later RD
command must be at this
packet position or later.
Read data from the same
device from an earlier RD
command must be at this
packet position or earier.
Transaction a2: CAL/SAM
a2 = {Da, Bx}
DQA5 of the first calibrate packet has the inverted TSQ bit of INIT
control register; i.e. logic 0 or high voltage means hot temperature.
When used for monitoring, it should be enabled with the DQA3
bit (current control one value) in case there is no RDRAM present:
HotTemp = /DQA5
•DQA3
Note that DQB3 could be used instead of DQA3.
tREADTOCC
Q (a1)
Q (a1)
CCSAMTOREAD
t
Figure 25-2 Temperature Calibration (TCEN-TCAL) Transactions to RDRAM
CTM/CFM
DQA8..0
DQB8..0
COL4
..COL0
ROW2
..ROW0
T0
T4
T8
T12
T1
T5
T9
T13
T2
T6
T10
T14
T3
T7
T11
T15 T16
T20
T24
T28
T17
T21
T25
T29
T18
T22
T26
T30
T19
T23
T27
T31 T32
T36
T40
T44
T33
T37
T41
T45
T34
T38
T42
T46
T35
T39
T43
T47
CA L
TCEN
TCAL
TCEN
tTCAL
Any ROW packet may be
placed in the gap between the
ROW packets with the
TCEN and TCAL commands.
No read data from devices
being calibrated
tTEMP
tTCEN
tTCQUIET



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com