| Electronic Components Datasheet Search |
|
DP83843 Datasheet(PDF) 24 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
DP83843 Datasheet(HTML) 24 Page - National Semiconductor (TI) |
|
24 / 87 page ![]() 2.0 Functional Description (Continued) 24 www.national.com packets with inverted End-of-Packet pulses are received, bad polarity is reported. A polarity reversal can be caused by a wiring error at either end of the cable, usually at the Main Distribution Frame (MDF) or patch panel in the wiring closet. The bad polarity condition is latched and the LED_ FDPOL output is asserted. The DP83843's 10BASE-T transceiver module corrects for this error internally and will continue to decode received data correctly. This eliminates the need to correct the wiring error immediately. 2.4.9 10BASE-T Internal Loopback When the 10MB_ENDEC_LB bit in the LBR (bit 4, register address 17h) is set, 10BASE-T transmit data is looped back in the ENDEC to the receive channel. The transmit drivers and receive input circuitry are disabled in trans- ceiver loopback mode, isolating the transceiver from the network. Loopback is used for diagnostic testing of the data path through the transceiver without transmitting on the network or being interrupted by receive traffic. This loopback func- tion causes the data to loopback just prior to the 10BASE-T output driver buffers such that the entire transceiver path is tested. 2.4.10 Transmit and Receive Filtering External 10BASE-T filters are not required when using the DP83843 as the required signal conditioning is integrated. Only isolation/step-up transformers and impedance match- ing resistors are required for the 10BASE-T transmit and receive interface. The internal transmit filtering ensures that all the harmonics in the transmit signal are attenuated by at least 30 dB. 2.4.11 Encoder/Decoder (ENDEC) Module The ENDEC module consists of essentially four functions: The oscillator generates the 10 MHz transmit clock signal for system timing from an external 25 MHz oscillator. The Manchester encoder accepts NRZ data from the con- troller or repeater, encodes the data to Manchester, and transmits it differentially to the transceiver, through the dif- ferential transmit driver. The Manchester decoder receives Manchester data from the transceiver, converts it to NRZ data and recovers clock pulses for synchronous data transfer to the controller or repeater. The collision monitor indicates to the controller the pres- ence of a valid 10 Mb/s collision signal. 2.4.12 Manchester Encoder The encoder begins operation when the Transmit Enable input (TX_EN) goes high and converts the NRZ data to pre-emphasized Manchester data for the transceiver. For the duration of TX_EN remaining high, the Transmit Data (TPTD +/−) is encoded for the transmit-driver pair (TPTD +/−). TXD must be valid on the rising edge of Trans- mit Clock (TX_CLK). Transmission ends when TX_EN deasserts. The last transition is always positive; it occurs at the center of the bit cell if the last bit is a one, or at the end of the bit cell if the last bit is a zero. 2.4.13 Manchester Decoder The decoder consists of a differential receiver and a PLL to separate a Manchester encoded data stream into internal clock signals and data. The differential input must be exter- nally terminated with either a differential 100ohm termina- tion network to accommodate UTP cable. The decoder detects the end of a frame when no more mid- bit transitions are detected. Within one and a half bit times after the last bit, carrier sense is de-asserted. Receive clock stays active for five more bit times after CRS goes low, to guarantee the receive timings of the controller or repeater. 2.5 100 BASE-FX The DP83843 is fully capable of supporting 100BASE-FX applications. 100BASE-FX is similar to 100BASE-TX with the exceptions being the PMD sublayer, lack of data scram- bling, and signaling medium and connectors. Chapter 26 of the IEEE 802.3u specification defines the interface to this PMD sublayer. The DP83843 can be configured for 100BASE-FX opera- tion either through hardware or software. Configuration through hardware is accomplished by forcing the FXEN pin (pin 21) to a logic low level prior to power-up/reset. Config- uration through software is accomplished by setting bits 9:7 of the LBR register to <011>, enabling FEFI (bit 14 of regis- ter PCSR(16h)), bypassing the scrambler (bit 12 of register LBR(17h)) and disabling Auto-Negotiation. In addition, set- ting the FX_EN bit of the PHYCTRL register (bit 5, address 19h) accomplishes the same function as forcing the FXEN pin (pin 21) to a logic low. In 100BASE-FX mode, the FX interface is enabled along with the Far End Fault Indication (FEFI) and Bypass Scrambler functions. Auto-Negotiation must be disabled in order for 100BASE-FX operation to work properly. The diagram in Figure 11 is a block diagram representation of the FX interface and the alternative data paths for trans- mit, receive and signal detect. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |