16 / 87 page ![]() 2.0 Functional Description (Continued) 16 www.national.com The code-group encoder converts 4 bit (4B) nibble data generated by the MAC into 5 bit (5B) code-groups for trans- mission. This conversion is required to allow control data to be combined with packet data code-groups. Refer to Table 2 for 4B to 5B code-group mapping details. The code-group encoder substitutes the first 8 bits of the MAC preamble with a J/K code-group pair (11000 10001) upon transmit. The code-group encoder continues to replace subsequent 4B preamble and data nibbles with corresponding 5B code-groups. At the end of the transmit packet, upon the deassertion of Transmit Enable signal from the MAC or Repeater, the code-group encoder injects the T/R code-group pair (01101 00111) indicating the end of frame. After the T/R code-group pair, the code-group encoder continuously injects IDLEs into the transmit data stream until the next transmit packet is detected (reassertion of Transmit Enable). The DP83843 also incorporates a special injection function which allows for fixed transmission of special repeating pat- terns for testing purposes. These special patterns are not delimited with Start of Stream Delimiter (SSD) or End of Stream Delimiter (ESD) code-groups and should not be enabled during normal network connectivity. These patterns, selectable via bits [8:7] of PCRS (address 16h), include: 8=0, 7=0: Normal operation (injection disabled) 8=0, 7=1: Transmit repeating FEFI pattern 8=1, 7=0: Transmit repeating 1.28 µs period squarewave 8=1, 7=1: Transmit repeating 160 ns period squarewave Note that these patterns will be routed through the transmit scrambler and become scrambled (and therefore poten- tially less useful) unless the scrambler is bypassed via bit 12 of LBR (address 17h). It should be noted that if the scrambler is bypassed by forcing the FXEN pin (and subse- quently resetting the device) the TPTD +/− outputs will become disabled and the test pattern data will be routed to the FXTD/AUITD +/− outputs. Additionally, the test patterns will not be generated if the DP83843 is in symbol mode. 2.2.1 Scrambler The scrambler is required to control the radiated emissions at the media connector and on the twisted pair cable (for 100BASE-TX applications). By scrambling the data, the total energy launched onto the cable is randomly distrib- uted over a wide frequency range. Without the scrambler, energy levels at the PMD and on the cable could peak beyond FCC limitations at frequencies related to repeating 5B sequences (i.e., continuous transmission of IDLEs). The scrambler is configured as a closed loop linear feed- back shift register (LFSR) with an 11-bit polynomial. The output of the closed loop LFSR is combined with the NRZ 5B data from the code-group encoder via an X-OR logic function. The result is a scrambled data stream with suffi- cient randomization to decrease radiated emissions at cer- tain frequencies by as much as 20 dB. The DP83843 uses the PHYID as determined by the PHYAD [4:0] pins to set a unique seed value for the scrambler so that the total energy produced by a multi-PHY application (i.e. repeater) distrib- utes the energy out of phase across the spectrum and helps to reduce overall electro-magnetic radiation. The scrambler is automatically bypassed when the DP83843 is placed in FXEN mode via hardware or, alterna- tively, controlled by bit 12 of LBR (address 17h) via soft- ware. 2.2.2 NRZ to NRZI Encoder After the transmit data stream has been scrambled and serialized, the data must be NRZI encoded in order to com- ply with the TP-PMD standard for 100BASE-TX transmis- sion over Category-5 unshielded twisted pair cable. There is no ability to bypass this block within the DP83843. 2.2.3 Binary to MLT-3 Convertor / Common Driver The Binary to MLT-3 conversion is accomplished by con- verting the serial binary datastream output from the NRZI encoder into two binary data streams with alternately phased logic one events. These two binary streams are then fed to the twisted pair output driver which converts these streams to current sources and alternately drives either side of the transmit transformer primary winding resulting in a minimal current (20 mA max) MLT-3 signal. Refer to Figure 4 . Figure 1. Binary to MLT-3 conversion D Q Q CP binary_in binary_plus binary_minus binary_in binary_plus binary_minus COMMON DRIVER MLT-3 differential MLT-3 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |