13 / 23 page ![]() HTU20D(F) RH/T SENSOR IC Digital Relative Humidity sensor with Temperature output SENSOR SOLUTIONS /// HPC202_5 HTU20D(F) Sensor Datasheet 9/2015 Page 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 S 1 0 0 0 0 0 0 0 ACK 1 1 1 1 0 1 0 1 ACK I²C address + write Command (see table p.9) 19 20 21 22 23 24 25 26 27 Measurement S 1 0 0 0 0 0 0 1 NACK measuring I²C address + read 19 20 21 22 23 24 25 26 27 Measurement S 1 0 0 0 0 0 0 1 ACK continue measuring I²C address + read 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 0 1 1 1 1 1 0 0 ACK 1 0 0 0 0 0 1 0 ACK Data (MSB) Data (LSB) Status 46 47 48 49 50 51 52 53 54 1 0 0 1 0 1 1 1 NACK P Checksum No Hold Master communication sequence Grey blocks are controlled by HTU20D(F) sensor. For Hold Master sequence, bit 45 may be changed to NACK followed by a stop condition to omit checksum transmission. For No Hold Master sequence, if measurement is not completed upon “read” command, sensor does not provide ACK on bit 27 (more of these iterations are possible). If bit 45 is changed to NACK followed by stop condition, checksum transmission is omitted. In those examples, the HTU20D(F) sensor output is SRH = ‘0111’1100’1000’0000 (0x7C80). For the calculation of physical values status bits must be set to ‘0’. Refer to “Conversion of signal outputs” section p.16. The maximum duration for measurement depends on the type of measurement and resolution chosen. Maximum values shall be chosen for the communication planning of the MCU. Refer to the table p.4 and p.6 regarding measuring time specifications. I²C communication allows for repeated start conditions without closing prior sequence with stop condition. Soft reset This command is used for rebooting the HTU20D(F) sensor switching the power off and on again. Upon reception of this command, the HTU20D(F) sensor system reinitializes and starts operation according to the default settings with the exception of the heater bit in the user register. The soft reset takes less than 15ms. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 S 1 0 0 0 0 0 0 0 ACK 1 1 1 1 1 1 1 0 ACK P I²C address + write Soft Reset Command Grey blocks are controlled by HTU20D(F) sensor. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |