Back Button AD9208 Datasheet HTML 79Page - Analog Devices AD9208 Datasheet HTML 80Page - Analog Devices AD9208 Datasheet HTML 81Page - Analog Devices AD9208 Datasheet HTML 82Page - Analog Devices AD9208 Datasheet HTML 83Page - Analog Devices AD9208 Datasheet HTML 84Page - Analog Devices AD9208 Datasheet HTML 85Page - Analog Devices AD9208 Datasheet HTML 86Page - Analog Devices AD9208 Datasheet HTML 87Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 83 / 137 page
background image
AD9208
Data Sheet
Rev. 0 | Page 82 of 136
SYSREF INPUT
The SYSREF input signal is used as a high accuracy system
reference for deterministic latency and multichip synchro-
nization. The AD9208 accepts a single-shot or periodic input
signal. The SYSREF mode select bits (Register 0x0120, Bits[2:1])
select the input signal type and also arm the SYSREF state
machine when set. If in single (or N) shot mode (Register 0x0120,
Bits[2:1] = 2), the SYSREF mode select bit self clears after the
appropriate SYSREF transition is detected. The pulse width
must have a minimum width of two CLK± periods. If the clock
divider (Register 0x010B, Bits[3:0]) is set to a value other than
divide by 1, multiply this minimum pulse width requirement by
the divide ratio (that is, if set to divide by 8, the minimum pulse
width is 16 CLK± cycles). When using a continuous SYSREF
signal (Register 0x0120, Bits[2:1] = 1), the period of the SYSREF
signal must be an integer multiple of the LMFC. LMFC can be
derived using the following formula:
LMFC = ADC clock/(S × K)
where:
S is the JESD204B parameter for number of samples per converter.
K is the number of frames per multiframe.
The input clock divider, DDCs, signal monitor block, and
JESD204B link are all synchronized using the SYSREF± input when
in normal synchronization mode (Register 0x01FF, Bit 0 = 0).
The SYSREF± input can also be used to timestamp an ADC
sample to provide a mechanism for synchronizing multiple
AD9208 devices in a system. For the highest level of timing
accuracy, SYSREF± must meet setup and hold requirements
relative to the CLK± input. There are several features in the
AD9208 that can be used to ensure these requirements are met;
these features are described in the SYSREF Control Features
section.
SYSREF Control Features
SYSREF is used, along with the input clock (CLK), as part of a
source-synchronous timing interface and requires setup and
hold timing requirements of −65 ps and 95 ps relative to the
input clock (see Figure 123). The AD9208 has several features
that aid users in meeting these requirements. First, the SYSREF
sample event can be defined as either a synchronous low to high
transition or synchronous high to low transition. Second, the
AD9208 allows the SYSREF signal to be sampled using either
the rising edge or falling edge of the input clock. Figure 123,
Figure 124, Figure 125, and Figure 126 show all four possible
combinations.
The third SYSREF related feature available is the ability to
ignore a programmable number (up to 16) of SYSREF events.
The AD9208 is able to ignore N SYSREF events (note that the
SYSREF ignore feature is enabled by setting the SYSREF mode
register (Register 0x0120, Bits[2:1]) to 2'b10, which is labeled as
N-shot mode. This feature is useful for handling periodic SYSREF
signals, which need time to settle after startup. Ignoring SYSREF
until the clocks in the system have settled can avoid an inaccurate
SYSREF trigger. Figure 127 shows an example of the SYSREF
ignore feature when ignoring three SYSREF events.
CLK
SYSREF
KEEP OUT WINDOW
SYSREF
SAMPLE POINT
HOLD
REQUIREMENT
95ps
SETUP
REQUIREMENT
–65ps
Figure 123. SYSREF Setup and Hold Time Requirements—SYSREF Low to
High Transition Using Rising Edge Clock (Default)
CLK
SYSREF
SYSREF
SAMPLE POINT
HOLD
REQUIREMENT
95ps
SETUP
REQUIREMENT
–65ps
Figure 124. SYSREF Low to High Transition Using Falling Edge Clock Capture
(Register 0x0120, Bit 4 = 1’b0; Register 0x0120, Bit 3 = 1’b1)
CLK
SYSREF
SYSREF
SAMPLE POINT
HOLD
REQUIREMENT
95ps
SETUP
REQUIREMENT
–65ps
Figure 125. SYSREF High to Low Transition Using Rising Edge Clock Capture
(Register 0x0120, Bit 4 = 1’b1; Register 0x0120, Bit 3 = 1’b0)
SYSREF
SAMPLE POINT
CLK
SYSREF
HOLD
REQUIREMENT
95ps
SETUP
REQUIREMENT
–65ps
Figure 126. SYSREF High to Low Transition Using Falling Edge Clock Capture
(Register 0x0120, Bit 4 = 1’b1; Register 0x0120, Bit 3 = 1’b1)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com