20 / 40 page ![]() AD7879/AD7889 Data Sheet Rev. D | Page 20 of 40 CONVERSION TIMING Conversion timing or update rate is the rate at which the AD7879/AD7889 provides converted values from the ADC so that the XY positions in the touch screen can be updated. In other words, the update rate is the timing required to give valid measurements in the sequencer. Figure 29 shows conversion timing for a conversion sequence. F C D TMEASURE F C D TMEASURE F C D TMEASURE F C D F C D TMEASURE TMEASURE TMEASURE X+ × M × M × M × M × M × M Y+ Z1 Z2 VBAT/AUX TEMP Figure 29. Conversion Timing Sequence FCD is required before each touch screen measurement (X+, Y+, Z1, and Z2). This time is required to allow the screen inputs to settle before converting. If the sequence does not contain any screen channel (VBAT, AUX, or TEMP), only one FCD is added at the start of the sequence. At the end of the sequence, there is always another FCD. TMEASURE is the time required to perform one measurement in the conversion sequence. TMEASURE = (ACQ (2 μs, 4 μs, 8 μs, 16 μs) + TCONV (7.5 μs) + TSORT (2 μs)) where: ACQ is the acquisition time which is programmable in Control Register 1. For temperature measurements, ACQ is fixed at 16 μs. TCONV (typical ADC conversion time) is specified at 7.5 μs. TSORT is the time needed to sort the new sample within the median filter array. The TSORT value is approximately 2 μs. If a median filter is not used (MED =0), the TSORT value is 0. TMEASURE_MIN = 9.5 μs (ACQ = 2 μs, no median filter) Conversion time per channel depends on the number of samples to be converted. The number of samples is pro- grammed using the following median filter settings: TCHANNEL = TMEASURE × MED TCHANNEL_MIN =9.5 μs (ACQ = 2 μs, MED = 0) TCHANNEL_MAX = 376 μs (ACQ = 16 μs, MED = 16) Update Rate = (FCD + (TMEASURE × MED)) × N + FCD + TMR where: MED = median filter setting (1, 4, 8, 16). N = number of channels to be measured (1 to 6). TMR = timer setting (0 μs to 9.4 ms). The total update rate depends on the median filter settings and the number of channels in the conversion sequence. The timer setting (TMR) allows the user more flexibility to program the update rate. For example, if ACQ = 4 μs MED = 8 N = 2 FCD = 1.024 ms TMR = 620 μs TMEASURE = 4 + 7.5 + 2 = 13.5 μs TCHANNEL = (13.5 × 8) = 108 μs Then, Update Rate = (1024 + 108) × 2 + 1024 + 620 = 3.9 ms |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |