Back Button BMC156 Datasheet HTML 70Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 71Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 72Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 73Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 74Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 75Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 76Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 77Page - Bosch Sensortec GmbH BMC156 Datasheet HTML 78Page - Bosch Sensortec GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 74 / 141 page
background image
Data sheet
eCompass BMC156
Page 74
BST-BMC156-DS000-01 | Revision 1.0 | July 2014
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice. Not intended for publication.
Register 0x0B (INT_STATUS_2)
The register contains interrupt status flags. Each flag is associated with a specific interrupt
engine. It is set when the associated interrupt engine triggers. The setting of latch_int<3:0>
controls if the interrupt signal and hence the respective interrupt flag will be permanently
latched, temporarily latched or not latched. The interrupt function associated with a specific
status flag must be enabled.
Name
0x0B
INT_STATUS_2
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset
Value
n/a
n/a
n/a
n/a
Content
tap_sign
tap_first_z
tap_first_y
tap_first_x
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset
Value
n/a
n/a
n/a
n/a
Content
slope_sign
slope_first_z
slope_first_y
slope_first_x
tap_sign:
sign of single/double tap triggering signal was ‘0’positive, or ‘1’ negative
tap_first_z:
single/double tap interrupt: ‘1’  triggered by, or ‘0’not triggered by z-axis
tap_first_y:
single/double tap interrupt: ‘1’  triggered by, or ‘0’not triggered by y-axis
tap_first_x:
single/double tap interrupt: ‘1’  triggered by, or ‘0’not triggered by x-axis
slope_sign:
slope sign of slope tap triggering signal was ‘0’positive, or ‘1’ negative
slope_first_z:
slope interrupt: ‘1’  triggered by, or ‘0’not triggered by z-axis
slope_first_y:
slope interrupt: ‘1’  triggered by, or ‘0’not triggered by y-axis
slope_first_x:
slope interrupt: ‘1’  triggered by, or ‘0’not triggered by x-axis



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com