| Electronic Components Datasheet Search |
|
ADPD4000 Datasheet(PDF) 34 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADPD4000 Datasheet(HTML) 34 Page - Analog Devices |
|
34 / 82 page ![]() ADPD4000/ADPD4001 Data Sheet Rev. A | Page 34 of 82 Table 22. Relevant Settings for Multiple Integration Mode Group Time Slot A Register Address1 Bit Field Name Description Multiple Integration Mode Using LED as Stimulus 0x0100 SAMPLE_TYPE_x Leave at the default setting (0) for default sampling mode. 0x0101 AFE_PATH_CFG_x Set to 0x1DA for TIA, BPF, integrator, and ADC. 0x0102 INPxx_x Enable desired inputs. 0x0103 PRECON_x Set to 0x5 to precondition anode of the photodiode to TIA_VREF. 0x0103 VCx_SEL_x Set to 0x2 to set ~250 mV reverse bias across photodiode. 0x0104 TIA_GAIN_CHx_x Select TIA gain. 0x0104 AFE_TRIM_VREF_x Set to 0x3 to set TIA_VREF = 1.27 V for maximum dynamic range. Timing 0x0107 NUM_INT_x Set to a number that utilizes most of the dynamic range of integrator available, leaving some margin for fluctuations in input level. 0x0107 NUM_REPEAT_x Set NUM_REPEAT_x to the number of times to repeat the multiple integration sequence. SNR increases by a factor of √(NUM_REPEAT_x). Total number of pulses is equal to NUM_REPEAT_x × NUM_INT_x. 0x010A INTEG_WIDTH_x Integration time in µs. Set to LED_WIDTH_x + 1. 0x010B INTEG_OFFSET_x, INTEG_FINE_OFFSET_x Integration sequence start time = INTEG_OFFSET_x + INTEG_FINE_OFFSET_x. Optimize as described in the Optimizing Position of Integration Sequence section. LED Settings 0x0105, 0x0106 LED_DRIVESIDEx_x Select LED for time slot used. 0x0105, 0x0106 LED_CURRENTx_x Set LED current for selected LED. 0x0109 LED_OFFSET_x Sets start time of first LED pulse in 1 μs increments. 0x10 default (16 μs). 0x0109 LED_WIDTH_x Sets width of LED pulse in 1μs increments. 2 μs or 3 μs recommended. 1 This is the Time Slot A register address. Add 0x020 for the identical register address for each subsequent time slot. For example, Register 0x0100 is the location for SAMPLE_TYPE_A. For Time Slot B, this register is at Address 0x0120, For Time Slot C, this register is at Address 0x0140. For Time Slot D, this register is at Address 0x0160, and so on. DIGITAL INTEGRATION MODE The ADPD4000/ADPD4001 support a digital integration mode to accommodate sensors that require longer pulses than can be supported in the typical analog integration modes. Digital integration mode also allows the system to use a larger LED duty cycle than the analog integration modes, which may result in the highest achievable levels of SNR. TIA RF RF TIA_VREF INx VCx BUF ADC Figure 41. Signal Path for Digital Integration Mode In digital integration mode, the BPF is bypassed and the integrator is configured as a buffer, resulting in the signal path shown in Figure 41. Digital integration regions are configured by the user and separated into lit and dark regions. The LED is pulsed in the lit region, and the LED is off in the dark region. ADC samples are taken at 1 μs intervals within the lit and dark regions and are then digitally integrated. The integration of the ADC samples from the dark region is subtracted from the integration of the ADC samples from the lit region and the result is written into the relevant signal output data registers. The sum of the samples from just the dark region are available in the dark output data registers. Both signal and dark values can be written to the FIFO. The ADPD4000/ADPD4001 support one-region and two-region digital integration modes. In one-region digital integration mode, an equal number of dark and lit samples are taken where all of the dark samples are taken in the dark region just prior to the lit region. One-region digital integration mode is illustrated in the timing diagram in Figure 42. In two-region digital integration mode, an equal number of dark and lit samples are taken. However, the dark region is split such that half of the samples are taken in the dark region prior to the lit region, and the other half is taken in the dark region following the lit region. The two-region digital integration mode results in higher ambient light rejection than the one-region digital integration mode in situations with a varying ambient light level. A timing diagram for two-region digital integration mode is shown in Figure 43. Table 23 shows the relevant register settings for the digital integration modes of operation. Note that only a single channel can be used in digital integration mode. Two channels are not supported for digital integration mode of operation. The MIN_ PERIOD_x bit field must also be manually set with the correct period because the minimum period is not automatically calculated in digital integration mode. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |