36 / 40 page ![]() MLX90821 Relative Pressure Sensor IC Page 36 of 40 REV 004 – 4 MAR 2021 3901090821 SENT Timings Parameter Symbol Comment Min Typ Max Unit SENT frame period tframe Shortest message (without pause pulse) and longest message (pause pulse enabled). Example in µs calculated using a 3µs tick time. 154 462 282 846(8) ticks µs Start-up time (to first falling edge) tsu1 Based on default settings. 0.7 1 1.1 ms Start-up time (up to first data received) tsu2 First SENT frame contains valid pressure data. Calculation based on 3µs tick time. 1.946(8) ms Table 28: Start-up timings Data Data Data VDD OUT tsu2 tsu1 tframe Figure 12: Start-up timings 8 Using nominal tick time, excluding tick time variations. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|