Electronic Components Datasheet Search
  English  ▼

X  

LTC3613 Datasheet(PDF) 17 Page - Analog Devices

Part # LTC3613
Description  25A Monolithic Synchronous DC/DC Step-Down Converter with PMBus Interface
PDF  44 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AD [Analog Devices]
Direct Link  http://www.analog.com
Logo AD - Analog Devices

LTC3613 Datasheet(HTML) 17 Page - Analog Devices

Back Button LTC3613 Datasheet HTML 13Page - Analog Devices LTC3613 Datasheet HTML 14Page - Analog Devices LTC3613 Datasheet HTML 15Page - Analog Devices LTC3613 Datasheet HTML 16Page - Analog Devices LTC3613 Datasheet HTML 17Page - Analog Devices LTC3613 Datasheet HTML 18Page - Analog Devices LTC3613 Datasheet HTML 19Page - Analog Devices LTC3613 Datasheet HTML 20Page - Analog Devices LTC3613 Datasheet HTML 21Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 44 page
background image
LTC7131-1
17
Rev. 0
For more information www.analog.com
OPERATION
with the master. The RUN_STBY pins are also connected
together as a handshaking signal between the two so that
both will shutoff together in case of a fault in only one of
the phases, such as overtemperature condition.
See the Applications Information section for further
details regarding 2-phase operation.
Discontinuous/Forced Continuous Operation
The LTC7131-1 can operate in one of two modes select-
able with the MODE/SYNC pin: discontinuous mode or
forced continuous mode. Connecting the MODE/SYNC
pin to INTVCC selects discontinuous mode. Discontinuous
mode is selected when high efficiency at very light loads is
desired. In this mode, when the inductor current reverses,
the bottom MOSFET turns off to minimize the efficiency
loss due to reverse current flow. This reduces the con-
duction loss and slightly improves the efficiency. As the
load reduces, the driver switching frequency drops in
proportion to the load, which further improves efficiency
by minimizing gate charge losses.
Forcing the MODE/SYNC pin low enables forced contin-
uous mode operation. In forced continuous mode, the
bottom MOSFET is always on when the top MOSFET
is off, allowing the inductor current to reverse at low
currents. This mode is less efficient due to conduction
and switching losses, but has the advantage of better
transient response at low currents, constant frequency
operation, and the ability to maintain regulation when
sinking current.
During soft-start, the LTC7131-1 forces the controller to
operate in discontinuous mode until the soft-start volt-
age reaches the internal reference to guarantee smooth
startup into a precharged output capacitor. During margi-
ning transitions and overvoltage conditions, however, the
LTC7131-1 always operates in forced continuous mode
to allow the switcher to sink current.
Fault Response Programming
When an output overvoltage or overcurrent condition
occurs, the LTC7131-1’s response to the fault can be
programmed using the MFR_FAULT_RESPONSE com-
mand. Two fault response modes are available: (1) ignore
or (2) hiccup mode. The response can be independently
programmed for each type of fault.
If ignore option is chosen, the LTC7131-1 will attempt to
correct the fault using the control loop as it would any
time the output goes out of regulation.
If hiccup mode is chosen, a fault timer is started when the
fault is detected. During this time, the control loop tries to
correct the fault. If the fault is still present after the 100µs
timer delay, the drivers are turned off for a period equal to
about 10× the soft-start time (set by the soft-start capac-
itor) before turning the drivers back on and attempting
to regulate again (see timing diagram in Figure 2). The
LTC7131-1 will continue these restart cycles indefinitely
until the fault is removed.
An overvoltage fault response is initiated when the output
voltage exceeds the upper PGOOD threshold. An overcur-
rent fault is initiated when the ITH voltage reached the
clamp set by the ILIM pin.
Undervoltage Lockout
The LTC7131-1 has two functions that help protect the
controller in case of undervoltage conditions. A precision
Figure 2. Fault Response Timing to Overcurrent Event
DRIVERS ON
DRIVERS OFF
7131-1 F02
OVERCURRENT REMOVED
OVERCURRENT EVENT
TIMEOUT DELAY
VOUT
TRACK/SS
TIMEOUT DELAY
FAULT TIMEOUT ENABLED
VREF



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com