| Electronic Components Datasheet Search |
|
ZSSC3123AI2R Datasheet(PDF) 30 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZSSC3123AI2R Datasheet(HTML) 30 Page - Renesas Technology Corp |
|
30 / 62 page ![]() ZSSC3123 Datasheet Nov 19, 2021 Page 30 © 2021 Renesas Electronics Status Bits (I2C or SPI) PDM Output Definition 10BIN Not applicable Command Mode: The ZSSC3123 is in Command Mode. 11BIN Not used Not used Table 17. Diagnostic Detection I2C or SPI Output PDM Output Definition Saturated output 3FFFHEX High output (railed) level A diagnostic fault has occurred in normal operation (see the following table). Table 18. Normal Operation Diagnostic Table Diagnostic Type Definition Configuration Error Permanent An EEPROM or RAM parity error occurred in the initial loading of the configuration registers. RAM Parity Error Transient A RAM parity error occurred during a microcontroller instruction in the last measurement cycle. EEPROM Error Transient A double-bit error detection (DED) EEPROM error occurred in the last measurement cycle (see section 10.4.1). Math Warning Transient An internal math overflow has occurred in the last measurement cycle and the output might be invalid. 10.4.1 EEPROM Error Detection and Correction The contents of the EEPROM are protected via error checking and correction (ECC). Each of the 32 16-bit words contains 6 parity bits enabling single-bit error correction (SEC) and double-bit error detection (DED) per word. In Command Mode both SEC and DED errors are reported in the response byte (see section 11.3). If the fetched EEPROM data has a DED error, then the fetched data will be incorrect; however, if a SEC error was reported then the fetched data has been corrected, and it is the user’s choice to write the data back to attempt to correct the error. During Normal Operation Mode, a diagnostic will be flagged on any DED error, but an SEC error will be automatically corrected and not flagged as a diagnostic. 10.4.2 Alarm Diagnostics The alarm outputs do not report diagnostics. If diagnostics are needed with alarm outputs, then either digital or PDM outputs must also be used. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |