20 / 28 page ![]() AD7366/AD7367 Rev. 0 | Page 20 of 28 MODES OF OPERATION The mode of operation of the AD7366/AD7367 is selected by the (logic) state of the CNVST signal at the end of a conversion. There are two possible modes of operation: normal mode and shutdown mode. These modes of operation are designed to provide flexible power management options, which can be chosen to optimize the power dissipation/throughput rate ratio for differing application requirements. NORMAL MODE Normal mode is intended for applications needing fast throughput rates because the user does not have to worry about any power-up times (with the AD7366/AD7367 remaining fully powered at all times). Figure 22 shows the general mode of operation of the AD7366 in normal mode, while Figure 23 illustrates normal mode for the AD7367. The conversion is initiated on the falling edge of CNVST as described in the Circuit Information section. To ensure that the part remains fully powered up at all times, CNVST must be at logic state high prior to the BUSY signal going low. If CNVST is at logic state low when the BUSY signal goes low, the analog circuitry powers down and the part ceases converting. The BUSY signal remains high for the duration of the conversion. The CS pin must be brought low to bring the data bus out of three-state, subsequently 12 SCLK cycles are required to read the conversion result from the AD7366 while 14 SCLK cycles are required to read from the AD7367. The DOUT lines return to three-state when CS is brought high only. If CS is left low for a further 12 SCLK cycles for the AD7366 or 14 SCLK cycles for the AD7367, the result from the other on chip ADC is also accessed on the same DOUT line, as shown in Figure 27 and Figure 28 (see the Serial Interface section). Once 24 SCLK cycles have elapsed for the AD7366 and 28 SCLK cycles for the AD7367, the DOUT line returns to three- state when CS is brought high and not on the 24th or 28th SCLK falling edge. If CS is brought high prior to this, the DOUT line returns to three-state at that point. Thus, CS must be brought high once the read is completed, as the bus does not auto- matically return to three-state upon completion of the dual result read. Once a data transfer is complete and DOUTA and DOUTB have returned to three-state, another conversion can be initiated after the quiet time, tQUIET, has elapsed by bringing CNVST low again. CNVST BUSY SCLK t2 t1 t3 SERIAL READ OPERATION CS 1 12 tCONVERT tQUIET Figure 22. Normal Mode Operation for the AD7366 BUSY SCLK t2 t1 t3 SERIAL READ OPERATION CS 1 14 tCONVERT tQUIET CNVST Figure 23. Normal Mode Operation for the AD7367 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |