Back Button PL75-9 Datasheet HTML 77Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 78Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 79Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 80Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 81Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 82Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 83Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 84Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 85Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 81 / 141 page
background image
R
Trompeter Products Catalog - T21 Military/Aerospace
ISO 9001
Registered
(800) 982-2629
Fax: (818) 706-1040
www.trompeter.com
81
Signal transmission in
high frequency/high density applications
One way to characterize the electronics market is to break it
into two segments, components and interconnects. Within the
interconnect segment, some signals require ground shielding,
stripline and coax, for example, and some do not. Ground-
shielded signals are needed:
•
to protect the interior signal wire from signal degradation
or loss utilizing a specific dielectric material most adjacent
to the signal wire;
•
to geometrically contain or ground the electromagnetic
field associated with electromagnetic wave propagation;
and/or
•
to shield the signal from external noise or radiation, either
via leakage or induction, including the fields created by
adjacent wired energy, which is called crosstalk.
Within the shielded interconnects segment, there are hard
wired interconnects and disconnectable interconnects. It is the
latter type that is the topic of discussion here, where technol-
ogy drivers and performance issues will be presented.
Technology Drivers
The customer-driven need for more function and content, as
evidence in the next-generation Pentium microprocessors
and more widespread use of the World Wide Web, is driving
corresponding requirements for system bandwidth, signal
density and signal clarity.
Because bandwidth has become such an important issue,
fiber or light-based signal transmission is now a viable
technology, replacing copper-based electronic signals in
many instances. However, because the end termination
manifolds of light energy still must be a manageable junc-
tion of discreet clean/fast signals, the need for disconnectable
copper interconnects has actually increased.
In addition, using digital technology to achieve some of
these transmission objectives requires an even greater de-
gree of fault-free interconnect performance.
What was
once a slight rise in background static on an analog signal
at low frequency becomes the loss of an entire stream of
binary information in high frequency digital technology.
As wires have progressed from point-to-point continuity
paths to transmission lines, so connectors have had to
accommodate the performance nuances of higher frequency
and density. More information is being moved more rapidly
on smaller waveforms, and the resulting demand on connec-
tion is proportional.
Electrical Performance Issues
The most effective connectors are those that, once inserted in a
transmission line, disappear. That is, they behave as if there were
no connector pair present and the cable and the transmission
characteristics of the line predominate. In order to achieve this
state, the losses at the connector junction should be equal to or
less than the losses in the transmission line.
Frequency and Wavelength
Since wavelength and frequency are inversely related by the
constant "c" (speed of light in a vacuum), at higher frequencies,
the wavelengths become smaller. For example, in free space, the
wavelength at 1 MHz is approximately 300m or 980'; at 300
MHz, it is 1 m or 39"; and at 1 GHz, it is 30 cm or 1.2". This
reduced wavelength begins to approach typical electrical compo-
nent length, and at higher frequencies, it becomes significant.
By experience, the effect of a connector is usually of minimal
significance until its length approaches approximately 5 percent
of wave length being passed. In a physical transmission system,
waves do not travel the speed of light due to the drag of the
dielectric and conductor losses. For example, for typical connec-
tor and copper cable construction, the velocity of propagation is
approximately 67 percent of "c", which corresponds to an effec-
tive reduction in wavelength from approximately 39" at 300
MHz to approximately 26".
Five percent of this length is
approximately 1.3", which is about the length of a typical RF
connector pair.
Attenuation. Attenuation is the total amount measured in deci-
bels by which power received is less than power transmitted after
a device has been inserted, with corrections for frequency. Also
called insertion loss, attenuation applies to an entire connector/
cable system. It is the sum of the following four components:
1. copper loss, or resistance, in the conductors;
2. dielectric losses, as a result of the dielectric having high but
not infinite resistance, therefore dissipating some energy;
3. reflection losses, due to some of the signal being reflected at
various discontinuity; and
4. radiation losses, where the line acts like an antenna and
radiates electromagnetic energy at high frequency.
For connector characterization within microwave systems fre-
quencies (in the few hundred megahertz and well into the
gigahertz range) the reflection copper losses are the most signifi-
cant. Other losses present are primarily a result of the cable
assembly or design.
Figure 1.
Frequency's Effect on Return Loss
Measured
Return Loss
Condition
Impedance (avg.)
1-20 MHz
20-300 MHz
0.300-1 GHz
1. (75/50)
60.7Ω
>30 dB
23.7 dB
7.1 dB
2. (75/~75)
68.4Ω
>30 dB
24.5 dB
12.4 dB
3. (75/75)
73.7Ω
>30 dB
25.4 dB
21.5 dB



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com