Back Button PL75-9 Datasheet HTML 84Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 85Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 86Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 87Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 88Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 89Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 90Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 91Page - List of Unclassifed Manufacturers PL75-9 Datasheet HTML 92Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 88 / 141 page
background image
R
Trompeter Products Catalog - T21 Military/Aerospace
ISO 9001
Registered
(800) 982-2629
Fax: (818) 706-1040
www.trompeter.com
88
Electronic systems wiring & cable
Triax Cable
Triax cable is coax cable with an additional outer copper braid (insu-
lated from the signal carrying conductors) that acts as a true shield and
protects the enclosed coax conductors. This braid or shield is grounded
and passes both ground loop and capacitive field noise currents away
from the signal carrying coax, thereby greatly improving the “signal to
noise” ratio over standard coax cable.
Triax cable is also used in “Driven Shield” applications where the inner
conductor and the first braid are driven in parallel at the transmitting
end and work against the outer braid which is insulated above ground.
The inner braid is left floating at the receiving end, providing a “Fara-
day” shield between the inner conductor and outer braid. In this way
the cable's distributed capacitance is greatly reduced, thereby reduc-
ing cable losses and loading. This application is most effective in high
frequency transducer data systems where the distributed capacity in
coax cable limits the data accuracy. The two outer braids of the triax
cable can be used as a low-impedance (approximately 12 ohms) trans-
mission line to carry high-current pulses to low impedance laser lamps
or exploding bridge wire (EBW) ordnance systems. Triax cable and
connectors completely insulated from the ground are available for these
applications.
Twinax Cable
-Twinax cable is a two-conductor twisted balanced wire line with a spe-
cific impedance and a shielding braid around both wires. The twisting
of the two balanced-signal-carrying wires cancels any random induced
noise voltage pickup, giving protection against any low frequency mag-
netic noise passing through the copper braid. Trompeter’s twinax cable
design also lowers cable losses by adding two (2) dielectric fillers un-
der the braid which separates the braid away from the signal pair, thereby
lowering the leakage capacitance to ground. Additionally, the coverage
is improved to 90% by using more copper wire in the braid and weaving
it tighter. Like triax cable, Trompeter's twinax cable provides protection
against ground loops and capacitive fields. Twinax cable usefulness, how-
ever, is limited to approximately 15 MHz since it has rather high trans-
mission losses above this frequency. Twinax cable and concentric con-
nectors are available for low frequency, digital and video distribution
systems.
Radiated Fields
Where strong radiated noise fields exist, such as high powered ra-
dar, broadcast stations, power lines, fluorescent lighting, office
and industrial machinery, multiple cable runs, etc., the cable con-
ductors act as receiving antennas or secondary windings of trans-
formers and pick up externally generated noise. At higher frequen-
cies, a part of the energy associated with the fluctuating current of
charge in a conductor is radiated away from the conductor in the
form of electromagnetic radiation. Electromagnetic shields make
use of the fact that the electromagnetic radiation must simulta-
neously contain electric and magnetic fields in order to propagate
independently through space. Therefore, a shield designed to elimi-
nate electrostatic fields can be used to neutralize the electric field
component of an electromagnetic wave. Consequently the outer con-
ductor of a coax cable connected to a ground through a low-imped-
ance path will be an effective shield against electromagnetic inter-
ference.
In high-level RF environments, it is desirable to minimize the RF
potentials existing between points on a coax shield. The shield
should be grounded at both ends of the cable and at intermediate
points along the cable. This multi-point grounding of the shield
maintains the RF shielding effectiveness of the cable. If coax cable
is used in a radiated interference area, the outer conductor should
be grounded as often as possible and wherever feasible in order to
remove the radiated interference as soon as possible. If your appli-
cation requires that you address both ground loops and radiated
interference, you may need to use either twinax or triax cable.
A particularly bad source of noise pickup is the induced currents
(cross-talk) encountered in large multiple cable installations.
Two improved types of cables are used for additional protection
against these radiated sources:
Source
Load
RF Interference
(Cable acts as antenna)
Source
Load
Magnetic Fields
Source
Load
Cross Talk
I N
Source
Load
Triax Cables Provide Additional
Shield, Insulated from Signal Carrying Coax
I N
Triax Driven Shield
Load
Source
Twinax Cable Provides A Shield, Insulated from
The Twisted Pair Signal Carrying Conductors
Load
Source
I N



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com