Electronic Components Datasheet Search
  English  ▼

X  

MP6527 Datasheet(PDF) 15 Page - Monolithic Power Systems

Part # MP6527
Description  40V, 0.8A, 10-Channel, Half-Bridge Motor Driver with Serial Input Control
PDF  24 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MPS [Monolithic Power Systems]
Direct Link  http://www.monolithicpower.com
Logo MPS - Monolithic Power Systems

MP6527 Datasheet(HTML) 15 Page - Monolithic Power Systems

Back Button MP6527 Datasheet HTML 11Page - Monolithic Power Systems MP6527 Datasheet HTML 12Page - Monolithic Power Systems MP6527 Datasheet HTML 13Page - Monolithic Power Systems MP6527 Datasheet HTML 14Page - Monolithic Power Systems MP6527 Datasheet HTML 15Page - Monolithic Power Systems MP6527 Datasheet HTML 16Page - Monolithic Power Systems MP6527 Datasheet HTML 17Page - Monolithic Power Systems MP6527 Datasheet HTML 18Page - Monolithic Power Systems MP6527 Datasheet HTML 19Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 24 page
background image
MP6527
– 40V, 0.8A MOTOR DRIVER WITH SERIAL INPUT CONTROL
MP6527 Rev. 1.0
MonolithicPower.com
15
9/23/2021
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2021 MPS. All Rights Reserved.
1
HBCNF7
Configures half-bridge 7.
1: The HS half-bridge is on and the LS half-bridge is off
0: The HS half-bridge is off and the LS half-bridge is on
0
OVLO
Enables VSx OVLO.
1: Enabled
0: Disabled
Note:
7) All input bits are set to 0 after VCC power-on reset.
Table 3: Output Diagnostic Registers (Channels 1 to 6, Input Bit[14] = 0)
Channels 1 to 6 (Input Bit[14] = 0)
Bit
Input Register
Function
PRE_15
TSD
Latched thermal shutdown (TSD). This bit is latched, and the corresponding
output is switched off. This bit can only be reset via status register reset (SRR)
or a power-on reset.
1: Fault
0: No fault
15
OC
(HB [6:1])
Latched over-current (OC) shutdown. This bit is set and latched if a half-bridge
from HB1 to HB6 has an overload or short-circuit. The corresponding output is
also switched off. This bit can only be reset via SRR or a power-on reset.
1: Fault
0: No fault
14
PSF
Power supply failure. This bit is set and latched if a VS1, VS2, or VS1 and VS2
over-voltage (OV) or under-voltage (UV) conditions occurs. All outputs are
switched off. This bit resets automatically if VSx returns to its normal operating
range.
1: Fault
0: No fault
13
OLD
(HB [6:1])
Open-load error. This bit is set and latched if a half-bridge from HB1 to HB6
experiences an open-load or under-load error condition. The corresponding
output is also switched off if input bit[13] (OLD_SD) is high. This bit can only be
reset via SRR or a power-on reset.
1: Fault
0: No fault
12
SHBEN6
Returns half-bridge 6
’s output status.
1: HB6 is active
0: HB6 is in Hi-Z
11
SHBEN5
Returns half-
bridge 5’s output status.
1: HB5 is active
0: HB5 is in Hi-Z
10
SHBEN4
Returns half-
bridge 4’s output status.
1: HB4 is active
0: HB4 is in Hi-Z



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com