Back Button AD9785-EBZ Datasheet HTML 41Page - Analog Devices AD9785-EBZ Datasheet HTML 42Page - Analog Devices AD9785-EBZ Datasheet HTML 43Page - Analog Devices AD9785-EBZ Datasheet HTML 44Page - Analog Devices AD9785-EBZ Datasheet HTML 45Page - Analog Devices AD9785-EBZ Datasheet HTML 46Page - Analog Devices AD9785-EBZ Datasheet HTML 47Page - Analog Devices AD9785-EBZ Datasheet HTML 48Page - Analog Devices AD9785-EBZ Datasheet HTML 49Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 45 / 64 page
background image
AD9785/AD9787/AD9788
Rev. 0 | Page 45 of 64
6.
Read back sync timing error IRQ and sync timing error
type (Register 0x09, Bit 4). If sync timing error IRQ is high,
a sampling error has occurred, and sync timing error type
indicates whether the sampling error is due to a setup time
violation or a hold time violation.
Table 32 shows the register settings required to enable the pulse
mode synchronization feature.
Table 32. Register Settings for Enabling Pulse Sync Mode
Register
Bit
Parameter
Value
0x01
[13]
PN code sync enable
0
7.
Adjust the SYNC_I Delay [4:0] value until the sync timing
error IRQ is no longer present.
[12]
Sync mode select
0
[11]
Pulse sync enable
1
SYNCHRONIZING MULTIPLE DEVICES TO EACH
OTHER
0x03
[26]
SYNC_I enable
1
[25]
SYNC_O enable
0
[10]
Set high
1
The AD9785/AD9787/AD9788 synchronization engine uses
a PN code synchronization scheme to align multiple devices
within a system to the same DAC clock edge. The PN code
scheme synchronizes all the internal clocks, as well as the phase
accumulator of the NCO for all devices. With this scheme, one
device functions as the master, and the remainder of the devices
are configured as slaves.
Synchronization Timing Error Detection
The synchronization logic has error detection circuitry similar
to the input data timing. The Sync Timing Margin [3:0] variable
(Register 0x03) determines the setup and hold margin that the
synchronization interface needs for the SYNC timing error IRQ
to remain inactive (show error-free operation). Thus, the SYNC
timing error IRQ is set whenever the setup and hold margins
drop below the Sync Timing Margin [3:0] value and does not
necessarily indicate that the SYNC_I input was latched incorrectly.
The master device generates the PN encoded signal and drives
the signal out on the SYNC_O (SYNC_O+/SYNC_O−) output
pins. This signal is then sent to the SYNC_I (SYNC_I+/
SYNC_I−) inputs of all the slave devices and to itself. The slave
devices receive the code from the master and demodulate the
signal to produce a synchronization pulse every time a valid
code is received. The encoded signal of every device must be
sampled on the same DAC clock edge for the devices to be
properly synchronized. Therefore, it is extremely important that
the REFCLK signals arrive at all the devices with as little skew
between them as possible. In addition, the SYNC_I signals must
arrive at all the devices with as little skew as possible. At high
DACCLK frequencies, this requires using low skew clock
distribution devices to deliver the REFCLK and SYNC_I signals
and paying careful attention to printed circuit board signal
routing to equalize the trace lengths of these signals.
When a SYNC timing error IRQ is set, corrective action can
restore the timing margin. The device can be configured for
manual mode sync error monitoring and error correction.
Follow these steps to monitor SYNC_I setup and hold timing
margins in manual mode:
1.
Set sync error check mode (Register 0x03, Bit 18) = 0
(manual check mode).
2.
Set Sync Timing Margin [3:0] (Register 0x03, Bits [3:0]) =
0000 (timing margin to minimum value).
3.
Set SYNC_I Delay [4:0] (Register 0x03, Bits [23:19]) =
00000 (SYNC_I delay line to minimum value).
4.
Set sync port IRQ enable (Register 0x09, Bit 0) = 1.
5.
Write 1 to sync timing error IRQ (Register 0x09, Bit 6)
to clear.
SYSTEM CLOCK
LOW SKEW
CLOCK DRIVER
LOW SKEW
CLOCK DRIVER
MATCHED
LENGTH TRACES
MATCHED
LENGTH TRACES
REFCLK
TXENABLE
SYNC_I
REFCLK
TXENABLE
SYNC_I
OUT
OUT
SYNC_O
Figure 64. Multichip Synchronization in PN Code Mode



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com