19 / 29 page ![]() ���������������������������������������������������������������� Maxim Integrated Products 19 MAX14821 IO-Link Device Transceiver Status Register [R1, R0] = [0,0] Register Functionality The device has four 8-bit-wide registers for configuration and monitoring (Table 1). Table 1. Register Summary R1/R0 = Register address. REGISTER R1 R0 D7 D6 D5 D4 D3 D2 D1 D0 Status 0 0 WuInt DoFaultInt DiLvl QLvl C/QFaultInt UV33Int UV24Int OTempInt CQConfig 0 1 RxFilter HiSlew C/Q_N/P C/Q_PP C/QDEn Q RxDis C/QLoad DIOConfig 1 0 DoInv DoAv DoN/P DoPP DoEn DoBit LiDis DiLoad Mode 1 1 RST WuIntEn DoFault C/QFault UV24 OTemp UV33En LDO33Dis Bit D7 D6 D5 D4 D3 D2 D1 D0 Bit Name WuInt DoFaultInt DiLvl QLvl C/QFaultInt UV33Int UV24Int OTempInt Read/Write R R R R R R R R POR State 0 0 X X 0 0 0 0 Reset Upon Read Yes Yes No No Yes Yes Yes Yes X = Unknown. These bits are dependent on the DI logic and C/Q inputs. The Status register reflects the logic levels of C/Q and DI and shows the source of interrupts that cause an IRQ hardware interrupt. The IRQ interrupt is asserted when an alarm condition (OTemp, UV33Int, UV24, C/QFault, DoFault, WuInt) is detected. All bits in the Status register are read-only. The interrupt bits return to the default state after the Status register is read. If a C/Q or DO fault condition persists, the associated interrupt bits are immediately set after the Status register is read. BIT NAME DESCRIPTION D7 Wulnt Wake-Up Interrupt Request. WuInt is set when an IO-Link wake-up request pulse is detected on C/Q and the WuIntEn bit in the Mode register is set. IRQ asserts when WuInt is set to 1. Read the Status register to clear the WuInt bit and deassert IRQ. D6 DoFaultInt DO Fault Interrupt. DoFaultInt interrupt bit and DoFault bit (in the Mode register) are set when a fault condition occurs on the DO driver output. The device registers a fault condition when a short circuit or voltage fault is detected on DO (see the DO Fault Detection section for more information). IRQ asserts when DoFaultInt is 1. Read the Status register to clear the DoFaultInt bit and deassert IRQ. D5 DiLvl DI Logic Level. The DiLvl bit mirrors the current logic level at the DI input. It is the inverse of the LI output and is always active regardless of the state of the LiDis bit (Table 2). DiLvl does not affect IRQ. DiLvl is not changed when the Status register is read. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |