| Electronic Components Datasheet Search |
|
CT2566 Datasheet(PDF) 8 Page - Aeroflex Circuit Technology |
|
|
|||||||||||||||||||||||||||||
CT2566 Datasheet(HTML) 8 Page - Aeroflex Circuit Technology |
|
8 / 37 page ![]() Aeroflex Circuit Technology SCDCT2566 REV B 8/10/99 Plainview NY (516) 694-6700 8 message regardless of whether or not an error was detected during the processing of that message. LOOK-UP TABLES In RTU mode a Look-Up Table is provided to allow the CT2566 to store messages in distinct areas of RAM based upon the subaddress of the received command word. See RTU operation for details. The CT2566 uses the T/R and the five subaddress bits to form a pointer into the “current area” Look-Up Table. The first 32 words of this table are initialized by the user with the addresses of the data blocks to be used for receiving data into subaddress 0,1,2,…31. The next 32 words are initialized by the user with the address of the data blocks to be used when transmitting data from subaddress 0,1,2,…31. CT2566 REGISTERS The CT2566 is controlled through the use of three internal registers: the Interrupt Mask Register, Configuration Register, and Start/Reset Register. In addition, the CT2566 can access up to four external, user supplied registers. Possible external register applications include: defining the RTU address, storing a CPU Time Tag, and reading a captured Built-In-Test (BIT) Word from the 1553 interface unit. For further information, consult factory. Table 2 – Internal Registers Address Definition CT2566 Address Bits Definition A2 A1 A0 0 0 0 Interrupt Mask Register 0 0 1 Configuration Register 0 1 0 Not Used 0 1 1 Start/Reset Register (write only) 1 0 0 External Register 1 0 1 External Register 1 1 0 External Register 1 1 1 External Register 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 1 1 1 1 1 1 SUBSYSTEM FLAG SERVICE REQUEST BUSY DB ACCEPT STOP ON ERROR CONTROL AREA BIT B/A MT RTU/BC BIT DEFINITIONS SUBSYSTEM FLAG 1553 status word bit. SERVICE REQUEST 1553 status word bit. BUSY 1553 status word bit. DB ACCEPT 1553 status word bit. STOP ON ERROR Causes BC to stop at the end of current data block if an error is detected. CONTROL AREA B/A Used for double buffering (See Double Buffering). RTU/BC/MT Operating Mode. Bit 15 Bit 14 Mode 0 0 BC 0 1 MT 1 0 RTU 1 1 ILLEGAL Figure 8 – Configuration Register |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |