56 / 304 page ![]() 56 Am79C973/Am79C975 P R E L I M INARY Whenever the Am79C973/Am79C975 controller is the current bus master and a data parity error occurs, SINT (CSR5, bit 11) will be set to 1. When SINT is set, INTA is asserted if the enable bit SINTE (CSR5, bit 10) is set to 1. This mechanism can be used to inform the driver of the system error. The host can read the PCI Status register to determine the exact cause of the interrupt. The setting of SINT due to a data parity error is not dependent on the setting of PERREN (PCI Command register, bit 6). By default, a data parity error does not affect the state of the MAC engine. The Am79C973/Am79C975 con- troller treats the data in all bus master transfers that have a parity error as if nothing has happened. All network activity continues. Advanced Parity Error Handling For all DMA cycles, the Am79C973/Am79C975 control- ler provides a second, more advanced level of parity error handling. This mode is enabled by setting APER- REN (BCR20, bit 10) to 1. When APERREN is set to 1, the BPE bits (RMD1 and TMD1, bit 23) are used to indicate parity error in data transfers to the receive and transmit buffers. Note that since the advanced parity error handling uses an additional bit in the descriptor, SWSTYLE (BCR20, bits 7-0) must be set to 2 or 3 to program the Am79C973/Am79C975 controller to use 32-bit software structures. The Am79C973/Am79C975 controller will react in the following way when a data parity error occurs: s Initialization block read: STOP (CSR0, bit 2) is set to 1 and causes a STOP_RESET of the device. s Descriptor ring read: Any on-going network activity is terminated in an orderly sequence and then STOP (CSR0, bit 2) is set to 1 to cause a STOP_RESET of the device. s Descriptor ring write: Any on-going network activity is terminated in an orderly sequence and then STOP (CSR0, bit 2) is set to 1 to cause a STOP_RESET of the device. s Transmit buffer read: BPE (TMD1, bit 23) is set in the current transmit descriptor. Any on-going net- work transmission is terminated in an orderly se- quence. s Receive buffer write: BPE (RMD1, bit 23) is set in the last receive descriptor associated with the frame. Terminating on-going network transmission in an or- derly sequence means that if less than 512 bits have been transmitted onto the network, the transmission will be terminated immediately, generating a runt packet. If 512 bits or more have been transmitted, the message will have the current FCS inverted and appended at the next byte boundary to guarantee an FCS error is de- tected at the receiving station. APERREN does not affect the reporting of address parity errors or data parity errors that occur when the Am79C973/Am79C975 controller is the target of the transfer. Initialization Block DMA Transfers During execution of the Am79C973/Am79C975 con- troller bus master initialization procedure, the Am79C973/Am79C975 microcode will repeatedly re- quest DMA transfers from the BIU. During each of these initialization block DMA transfers, the BIU will perform two data transfer cycles reading one DWord per transfer and then it will relinquish the bus. When SSIZE32 (BCR20, bit 8) is set to 1 (i.e., the initialization block is organized as 32-bit software structures), there are seven DWords to transfer during the bus master ini- tialization procedure, so four bus master-ship periods are needed in order to complete the initialization se- quence. Note that the last DWord transfer of the last bus mastership period of the initialization sequence ac- cesses an unneeded location. Data from this transfer is discarded internally. When SSIZE32 is cleared to 0 (i.e., the initialization block is organized as 16-bit soft- ware structures), then three bus mastership periods are needed to complete the initialization sequence. The Am79C973/Am79C975 supports two transfer modes for reading the initialization block: non-burst and burst mode, with burst mode being the preferred mode when the Am79C973/Am79C975 controller is used in a PCI bus application. See Figure 23 and Figure 24. When BREADE is cleared to 0 (BCR18, bit 6), all initial- ization block read transfers will be executed in non- burst mode. There is a new address phase for every data phase. FRAME will be dropped between the two transfers. The two phases within a bus mastership pe- riod will have addresses of ascending contiguous or- der. When BREADE is set to 1 (BCR18, bit 6), all initializa- tion block read transfers will be executed in burst mode. AD[1:0] will be 0 during the address phase indicating a linear burst order. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |