| Electronic Components Datasheet Search |
|
ML7406 Datasheet(PDF) 64 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
ML7406 Datasheet(HTML) 64 Page - List of Unclassifed Manufacturers |
|
64 / 104 page ![]() FEDL7406-02 ML7406 64/104 ○CCA (Clear Channel Assessment) function ML7406 supports CCA function. CCA function is to make a judment wheher the specified frequency channel is in-use or available. Normal mode, continuous mode and IDLE detection mode are supported as following table. [CCA mode setting] [CCA_CTRL: B0 0x39] Bit4 (CCA_EN) Bit5 (CCA_CPU_EN) Bit6 (CCA_IDLE_EN) Normal mode 0b1 0b0 0b0 Continuous mode 0b1 0b1 0b0 IDLE detection mode 0b1 0b0 0b1 (1) Normal mode Normal mode determines IDLE or BUSY. CCA (Normal mode) will be executed when RX_ON is issued while CCA_EN(CCA_CTRL: B0 0x39(4)])=0b1, CCA_CPU_EN(CCA_CTRL: B0 0x39(5)])=0b0 and CCA_IDLE_EN (CCA_CTRL: B0 0x39(6)])=0b0 are set. Judgement of CCA is determined by average ED value and CCA threshold value defined by [CCA_LVL: B0 0x37] register. IF average ED value in [ED_RSLT: B0 0x3A] register exceeds the CCA threshold value, it is considered as “BUSY”. And CCA_RSLT[1:0]([CCA_CTRL: B0 0x39(1-0)]) =0b01 is set If average ED value is smaller than CCA threshold value and maintains IDLE detection period which is defined by IDLE_WAIT[9:0] of the [IDLE_WAIT_L: B0 0x3B], [IDLE_WAIT_H: B0 0x3C] registers. it is considered as “IDLE”. And CCA_RSLT[1:0]([CCA_CTRL: B0 0x39(1-0)])=0b00 is set. For details operation of CCA_IDLE_WAIT[9:0], please refer to ”IDLE detection for long time period” If BUSY or IDLE state is detected, CCA completion interrupt (INT[18] group3) is generated, CCA_EN bit is cleared to 0b0 automatically. Upon clearing CCA completion interrupt, CCA_RSLT[1:0]([CCA_CTRL: B0 0x39(1-0)]) are reset to 0b00. Therefore CCA_RSLT[1:0] should be read before clearing CCA completion interrupt. If ED value exceeds the value defined by [CCA_IGNORE_LVL: B0 0x36] register, and as long as a given ED value is included in the averaging target of ED value calculation, IDLE judgement is not performed. In this case if average ED value exceeds CCA threshold value, it is considered as “BUSY” and CCA is terminated. If average ED value is smaller than CCA threshold valu, IDLE judgement is not determined. And CCA_RSLT[1:0] ([CCA_CTRL: B0 0x39(1-0)]) indicates 0b11. CCA operation continues until BUSY is determined or gievn ED value is out of averaging target and IDLE is determined. For details operation of ED value execeeding [CCA_IGNORE_LVL: B0 0x36] register, please refer to ”IDLE determination exclusion under strong signal input”. Timming from CCA command issue to CCA completion is in the formula below. [IDLE detection] CCA execution timing = (ED value average times + IDLE_WAIT setting) * AD conversion time [BUSY detection] CCA execution time = ED value average time * AD conversion time (Note) 1. Above formula does not consider IDLE judgement exclusion based on [CCA_IGNORE_LVL: B0 0x36] register. For details, please refer to ”IDLE detection exclusion under strong signal input”. 2. AD conversion time can be slected by ADC_CLK_SEL([ADC_CLK_SET: B1 0x08(4)]). ADC_CLK_SEL=0b0:17.7μs , 0b1:16μs(default) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |