| Electronic Components Datasheet Search |
|
AS3630 Datasheet(PDF) 36 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3630 Datasheet(HTML) 36 Page - ams AG |
|
36 / 72 page ![]() AS3630 – 36 8A Supercap Flash Driver If the voltage on VDCDC reaches VVOUTMAX and the voltage across the current source between VDCDC and LED_OUT is below VFLASH_COMP an open LED is detected. If an open or shorted LED is detected, bit fault_led is set. The DCDCs and current sinks are disabled and the Supercap is discharged by setting mode_setting=001b. In external torch mode, the register txmask_torch_mode is reset. Note: Short/open LED detection is disabled in PWM operating mode (mode_setting=101b). The voltage on VDCDC will nevertheless never exceed VVOUTMAX. AS3630 DIE Overtemperature Detected - fault_overtemp The junction temperature of the AS3630 is continuously monitored. If the temperature exceeds TOVTEMP, the DCDCs are stopped, the current sources are disabled (instantaneous) and the bit fault_overtemp is set (but the operating mode mode_setting is not changed). The driver is automatically re-enabled once the junction temperature drops below TOVTEMP-TOVTEMPHYST. Note: If an overtemperature is detected in Supercap pre-charge, transition or charge mode, charging is temporarily disabled until the temperature drops, but the register bit fault_overtemp is not set. Timeout Fault - fault_timeout If the flash is started a timeout timer is started in parallel. If the flash duration defined by the STROBE input (strobe_on=1 and strobe_type=1, see Figure 31) exceeds tFLASHTIMEOUT (adjustable by register flash_timeout), the DCDCs are stopped and the flash current source (on pin LED_OUT ) is disabled (ramping down) and fault_timeout is set. If the flash duration is defined by the timeout timer itself (strobe_on = 0, see Figure 28), the register fault_timeout is not set after the flash has been finished. AS3630 will automatically select the operating mode according to register mode_after_flash shown in Figure 26. Supercap Short Detected - fault_sc_short In all operating modes except shutdown (mode_setting not 000b or 001b) once VSUPERCAP is above 2.4V both internal capacitors of the Supercap (VSUPERCAP-BAL and BAL-GND) are monitored if they are shorted. If any of them is shorted10, charging is stopped and the Supercap is discharged by setting mode_setting=001b andfault_sc_short is set. 10. VSUPERCAP-BAL is compared with typ. 950mV, BAL-GND is compared with typ. 700mV. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |