14 / 69 page ![]() 14 Maxim Integrated SFP Controller with Dual LDD Interface DS1876 corresponding alarms and warnings (TXP HI1, TXP LO1, TXP HI2, TXP LO2, BIAS HI1, and BIAS HI2) are asserted or deasserted. After resetting, the device completes one QT cycle before making comparisons. The TXP LO quick-trip alarm updates its alarm bit, but does not create FETG until after TXDEXT. TXP HI and BIAS HI can also be con- figured to wait for TXDEXT; however, this can be disabled using QTHEXT_ (Table 02h, Register 88h). Monitors and Fault Detection Monitors Monitoring functions on the DS1876 include six quick- trip comparators and six ADC channels. This monitoring combined with the alarm enables (Table 01h/05h) deter- mines when/if the DS1876 turns off DACs and triggers the TXFOUT and TXDOUT1, TXDOUT2 outputs. All the monitoring levels and interrupt masks are user program- mable. Six Quick-Trip Monitors and Alarms Six quick-trip monitors are provided to detect potential laser safety issues and LOS status. These monitor the following: 1) High Bias Current 1 (HBATH1), causing QT BIAS1 HI 2) Low Transmit Power 1 (LTXP1), causing QT TXP1 LO 3) High Transmit Power 1 (HTXP1), causing QT TXP1 HI 4) High Bias Current 2 (HBATH2), causing QT BIAS2 HI 5) Low Transmit Power 2 (LTXP2), causing QT TXP2 LO 6) High Transmit Power 2 (HTXP2), causing QT TXP2 HI The high and low transmit power quick-trip registers (HTXP1, HTXP2, LTXP1, and LTXP2) set the thresholds used to compare against the PMON1 and PMON2 volt- ages to determine if the transmit power is within speci- fication. The HBATH1 and HBATH2 QTs compare the BMON1 and BMON2 inputs (generally from the laser driver’s bias monitor output) against their threshold set- tings to determine if the present bias current is above specification. The bias and power QTs are routed to FETG through interrupt masks to allow combinations of these alarms to be used to trigger FETG. The bias and power QTs are directly connected to TXFOUT (see Figure 9). The user can program up to eight different temperature-indexed threshold levels for HBATH1 and HBATH2 (Table 06h, Registers E0h -E7h). Six ADC Monitors and Alarms The ADC monitors six channels that measure tem- perature (internal temp sensor), VCC, PMON1, PMON2, BMON1, and BMON2 using an analog multiplexer to measure them round-robin with a single ADC (see the ADC Timing section). The channels have a customer- programmable full-scale range, and all channels have a customer-programmable offset value that is factory pro- grammed to a default value (see Table 2). Additionally, PMON1, PMON2 and BMON1, BMON2 can right-shift results by up to 7 bits before the results are compared to alarm thresholds or read over the I2C bus. This allows customers with specified ADC ranges to calibrate the ADC full scale to a factor of 1/2n of their specified range to measure small signals. The DS1876 can then right- shift the results by n bits to maintain the bit weight of their specification. Figure 3. Quick-Trip Sample Timing Table 2. ADC Default Monitor Full-Scale Ranges QUICK-TRIP SAMPLE TIMES LTXP2 SAMPLE HBIAS1 SAMPLE HBIAS1 SAMPLE HBIAS2 SAMPLE HTXP1 SAMPLE HTXP2 SAMPLE LTXP1 SAMPLE LTXP2 SAMPLE tREP QT CYCLE SIGNAL (UNITS) +FS SIGNAL +FS HEX -FS SIGNAL -FS HEX Temperature (NC) 127.996 7FFF -128 8000 VCC (V) 6.5528 FFF8 0 0000 PMON1, PMON2 and BMON1, BMON2 (V) 2.4997 FFF8 0 0000 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |