Back Button LTC4261 Datasheet HTML 21Page - Analog Devices LTC4261 Datasheet HTML 22Page - Analog Devices LTC4261 Datasheet HTML 23Page - Analog Devices LTC4261 Datasheet HTML 24Page - Analog Devices LTC4261 Datasheet HTML 25Page - Analog Devices LTC4261 Datasheet HTML 26Page - Analog Devices LTC4261 Datasheet HTML 27Page - Analog Devices LTC4261 Datasheet HTML 28Page - Analog Devices LTC4261 Datasheet HTML 29Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 74 page
background image
LTC4283
25
Rev. B
For more information www.analog.com
APPLICATIONS INFORMATION
Case 1. If active current limit is engaged in normal opera-
tion (power good signals are asserted), the TMR pull-up
current of the LTC4283 is proportional to the attenu-
ated drain voltage of the MOSFET at DRNS (top line in
Figure 7). This is proportional to the power dissipation
since the current through the MOSFET is fixed during
current limit (provided that foldback is disabled in normal
operation by setting the FB_DIS bit in CONFIG_1 register
0x0D). The TMR pull-up current in this condition is:
ITMR(UP)=111.1
µA
V
⎡
⎣⎢
⎤
⎦⎥
• VDRNS+2µA
where 111.1µA/V is the transconductance. The TMR pull-
up current reaches 202µA at VDRNS = 1.8V, which is tested
and specified. The offset of 2μA is introduced to guarantee
a minimum pull-up current that prevents TMR from hang-
ing in a resistive short-circuit condition.
The above equation also applies to startup in dV/dt mode
(DVDT bit in CONTROL_1 register 0x0A = 1), when the
current limit is triggered under a fault condition such as
a short-circuit. The accelerated timeout combined with
startup foldback (see Current Limit Foldback) protects
MOSFET from overstress.
Case 2. During startup in dV/dt mode when current limit
is not engaged, TMR pull-up current is disabled:
ITMR(UP) = 0
In this case a 2μA pull down current holds TMR low if
the THERM_TMR bit in control register 0x0A is set. This
avoids undesired timeout before the load capacitor is fully
charged by the inrush current, which is set to such a low
level that the power dissipation in MOSFET is insignificant.
Case 3. If current limit is engaged during startup in current
limit mode (DVDT bit in CONTROL_1 register 0x0A = 0),
the TMR pull-up current is reduced by the foldback ratio:
ITMR(UP) = αSTARTUP •111.1
µA
V
⎡
⎣⎢
⎤
⎦⎥
• VDRNS +2µA
where aSTARTUP is the startup foldback ratio that is con-
trolled by the FB bits in CONFIG_1 register 0x0D (see
Current Limit Foldback). The reduction keeps the trans-
conductance unchanged compared to that in normal
operation with foldback disabled.
Case 4. If current limit is not engaged, either in normal
operation or during startup in current limit mode, the
TMR pull-up current is gated by the DRAIN voltage. If
DRAIN is lower than its threshold, VD,FET(TH), the TMR
pull-up current is disabled. VD,FET(TH) is programmable
from 72mV to 203mV in geometric scale using the VDTH
bits in CONFIG_2 register 0x0E. This is a typical case in
normal operating conditions when the MOSFET is fully
enhanced. If DRAIN is higher than VD,FET(TH), an internal
multiplier charges up TMR with a current approximately
proportional to power dissipation in the MOSFET:
If VSENSE 0.1VILIM,
ITMR(UP) =111.1
µA
V
• VDRNS •
VSENSE
VILIM
– 0.1
+ITMR(OS)
If VSENSE <0.1VILIM,
ITMR(UP) =ITMR(OS)
where ITMR(OS) has an approximate value of 2µA.
Figure 7 shows the TMR pull-up currents vs VDRNS at four
different ∆VSENSE levels below current limit.
If using an RC network representing the MOSFET thermal
model between TMR and VEE, the THERM_TMR bit in
CONTROL_1 register 0x0A must be set to 1 to disable
the internal 2μA pull-down current. The total resistance
in the RC network provides the discharge path to TMR.
Figure 7. TMR Pull-Up Current vs ∆VSENSE and DRNS Voltage
∆VSENSE =
100% VILIM
96.7% VILIM
50% VILIM
20% VILIM
10% VILIM
DRNS VOLTAGE (V)
0
0.5
1
1.5
2
2.5
3
0
50
100
150
200
250
300
350
4283 F07



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com