Electronic Components Datasheet Search
  English  ▼

X  

LTC4261 Datasheet(PDF) 28 Page - Analog Devices

Part # LTC4261
Description  Negative Voltage Hot Swap Controller with Energy Monitor
PDF  74 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AD [Analog Devices]
Direct Link  http://www.analog.com
Logo AD - Analog Devices

LTC4261 Datasheet(HTML) 28 Page - Analog Devices

Back Button LTC4261 Datasheet HTML 24Page - Analog Devices LTC4261 Datasheet HTML 25Page - Analog Devices LTC4261 Datasheet HTML 26Page - Analog Devices LTC4261 Datasheet HTML 27Page - Analog Devices LTC4261 Datasheet HTML 28Page - Analog Devices LTC4261 Datasheet HTML 29Page - Analog Devices LTC4261 Datasheet HTML 30Page - Analog Devices LTC4261 Datasheet HTML 31Page - Analog Devices LTC4261 Datasheet HTML 32Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 28 / 74 page
background image
LTC4283
28
Rev. B
For more information www.analog.com
APPLICATIONS INFORMATION
The LTC4283 foldback profile can differentiate an output
short fault from an allowed input step. Upon an output
short, RTNS – DRNS drops and current limit is folded
back to protect the MOSFET from overstress. In the event
of an input step, RTNS – DRNS increases while the load
is charged up. The current limit either stays constant or
approximates constant load power (based on the LPFB
bit) to approach the optimum output ramp and minimize
the temperature rise of the MOSFET (see Input Step and
Optimum Output Ramp). This is superior to a foldback
profile capacitance based upon VDS or power dissipation
of the MOSFET. In that case, the output short and input
step conditions cannot be differentiated, often resulting
in unwanted turn-off upon an input step.
Foldback in normal operation can be independently dis-
abled by setting the FB_DIS bit in the CONFIG_1 register
0x0D. With this configuration foldback is only effective
during startup, and it should only be used when an RC
network representing the thermal model of the MOSFET
is connected to TMR. If a single capacitor is used, it is
recommended to enable foldback in normal operation by
clearing the FB_DIS bit for more conservative protection
of the MOSFET. Note that the load power foldback con-
trolled by the LPFB bit is not affected by the FB_DIS bit.
FET Bad Fault and Auto-Retry
In a hot swap application several possible faults can
prevent the MOSFET from turning on fully. A damaged
MOSFET may have leakage from gate to drain or have
degraded RDS(ON). Debris on the board may also pro-
duce leakage or a short from the GATE pin to VEE or the
MOSFET drain. In these conditions the LTC4283 may not
be able to pull the GATE pin high enough to fully enhance
the MOSFET, or the MOSFET may not reach the intended
RDS(ON) when the GATE pin is fully enhanced. This can
put the MOSFET in a condition where the power in the
MOSFET is higher than its continuous power capability,
even though the current is below the current limit. The
LTC4283 monitors the integrity of the MOSFET in two
ways, and acts on both of them in the same manner.
First, the LTC4283 monitors the MOSFET drain voltage
at the DRAIN pin. A comparator detects a DRAIN high
condition whenever DRAIN is above a reference voltage,
VD,FET(TH) that can be configured to 72mV, 102mV,
143mV or 203mV (geometric scale) using the VDTH bits
in the CONFIG_2 register 0x0E. Second, the LTC4283
monitors the GATE voltage. If the MOSFET is turned on,
but the GATE voltage is lower than VIN – 1.8V, a GATE low
condition is detected.
When either a DRAIN high or a GATE low condition is
present when the MOSFET is commanded on, the FET_
BAD_STATUS bit in FAULT_STATUS register 0x03 is
set and an internal FET bad fault timer is started. The
FTBD_DL bits in CONFIG_2 register 0x0E configures the
timer duration to 256ms, 512ms, 1.02s and 2.05s. If
the DRAIN voltage falls below VD,FET(TH) and the GATE
low condition is cleared before the timer times out, the
FET_BAD_STATUS bit is cleared and the timer is reset.
If the timer does time out, the FET_BAD_FAULT bit in
FAULT register 0x04 is set and the MOSFET is turned off
if the FET_BAD_TURN_OFF bit in CONTROL_1 register
0x0A has been set. The DRAIN high condition also acti-
vates TMR pull-up current when not in current limit (see
SOA Timer).
Note that during startup while the load is being charged,
the FET_BAD_STATUS bit is set and the FET bad fault
timer is running. To avoid undesired turn-off, the timer
duration must be configured long enough for the load to
be fully charged.
After the MOSFET is turned off following a FET bad fault,
the FET_BAD_STATUS bit is cleared. The MOSFET is
allowed to turn on again after a cooling delay if the FET_
BAD_RETRY bits in CONTROL_2 register 0x0B have not
been cleared. The cooling delay is the same as that for an
overcurrent fault and is configurable from 512ms to 65.5s
in binary scale using the COOLING_DL bits in CONFIG_2
register 0x0E (see Table 11). During the cooling delay the
DELAY_STATUS bit in REBOOT register 0xA2 is set. It will
be cleared when the delay expires. The FET_BAD_RETRY
bits configures the number of retries following a FET bad
fault to 1, 7 or infinity (see Table 10). If a finite retry
number is selected, a retry counter reset timer of 16.4s is
started upon the retry following a FET bad fault. If the next
FET bad fault occurs before the timer expires, the retry
counter increments and the timer is reset. Otherwise the



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com