Back Button LTC4261 Datasheet HTML 22Page - Analog Devices LTC4261 Datasheet HTML 23Page - Analog Devices LTC4261 Datasheet HTML 24Page - Analog Devices LTC4261 Datasheet HTML 25Page - Analog Devices LTC4261 Datasheet HTML 26Page - Analog Devices LTC4261 Datasheet HTML 27Page - Analog Devices LTC4261 Datasheet HTML 28Page - Analog Devices LTC4261 Datasheet HTML 29Page - Analog Devices LTC4261 Datasheet HTML 30Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 74 page
background image
LTC4283
26
Rev. B
For more information www.analog.com
APPLICATIONS INFORMATION
The configuration of the RC network for a particular
MOSFET starts with selection of a desired number of
resistive and capacitive elements and their values in ther-
mal domain based on the thermal impedance plot pro-
vided by the MOSFET manufacturer. Three resistors and
three capacitors are usually enough to fit the plot fairly
well from 10μs to 100ms, which covers the timing range
of typical operating and fault conditions. Two resistors
and two capacitors may provide an acceptable accuracy
for some MOSFETs or conditions. If better fitting accuracy
or wider fitting range is desired, more elements may be
used. After the thermal RC network is configured, the
thermal quantities are then converted to electric quanti-
ties according to
RE=k •Rθ
CE=
Cθ
k
where RE and CE are electric resistance and capacitance,
respectively and Rθ and Cθ are thermal resistance and
capacitance, respectively. The conversion constant k is
given by
k =
VDS,MAX •ID,MAX
ITMR(UP),MAX
•
VTMR(TH)
ΔTMAX
where VDS,MAX and ID,MAX are the maximum drain-
to-source voltage and maximum drain current of the
MOSFET, respectively, ITMR(UP),MAX is the TMR pull-up
current corresponding to the maximum power dissipa-
tion PMAX = VDS,MAX • ID,MAX, VTMR(TH) is TMR threshold
voltage (2.048V), and ∆TMAX is the maximum allowable
temperature rise of the MOSFET. For example, if VDS,MAX
= 72V, ID,MAX = 32A, ITMR(UP),MAX = 202μA (at VDRNS
= 1.8V, in current limit) and ∆TMAX = 65°C (maximum
junction temperature of MOSFET = 150°C and ambient
temperature = 85°C), k = 3.6 • 105 [V2/°C]. An RC network
consisting of two resistors and capacitors that represent
the electric model for the thermal behavior of PSMN4R8-
100BSE is show in Figure 2a.
The LTC4283 also allows a single capacitor connected
between TMR and VEE (see Figure 13). In this case, the
THERM_TMR bit in the CONTROL_1 register must be
cleared to enable the internal 2μA pull-down current.
Once enabled, the 2μA pull-down current keeps TMR low
in normal conditions when the pull-up current is disabled.
When the pull-up current is enabled under fault conditions,
the 2μA pull-down is switched off. A minimum capaci-
tance must be selected to keep the MOSFET on during
worst-case operating conditions, and the MOSFET must
be selected to withstand the worst-case SOA condition
during normal operating or fault conditions. Regardless
of the value of the THERM_TMR bit, when EN# is higher
than its 1.28V threshold, TMR is discharged by a 5mA
current. When TMR is below 0.1V, the TMR_LOW bit in
SYSTEM_STATUS register 0x00 is set to 1.
Overcurrent Fault and Auto-Retry
Under an overcurrent condition, when the active current
limit loop is engaged and TMR is being charged up, the
overcurrent present bit, OC_STATUS, in FAULT_STATUS
register 0x03 is set. When the TMR voltage reaches its
2.048V threshold, the overcurrent fault bit, OC_FAULT, in
the FAULT register 0x04 is set and the GATE pin is pulled
down to turn off the MOSFET.
After the MOSFET is turned off, the OC_STATUS bit is
cleared. The MOSFET is allowed to turn on again after a
cooling delay if the OC_RETRY bits in CONTROL_2 register
0x0B have not been cleared. The auto-retry cooling delay
is configurable from 512ms to 65.5s in binary scale using
the COOLING_DL bits in CONFIG_2 register 0x0E (See
Table 11). During the cooling delay the DELAY_STATUS
bit in REBOOT register 0xA2 is set to 1 to indicate the delay
timer is running. It will be cleared when the delay expires.
The number of retries following an overcurrent fault can be
configured to 1, 7 or infinity using the OC_RETRY bits (see
Table 10). If a finite retry number is selected, a retry coun-
ter reset timer of 16.4s is started upon the retry following
an overcurrent fault. If the next overcurrent fault occurs
before the timer times out, the retry counter increments
and the timer is restarted. Otherwise the retry counter
is restarted. When the programmed number of retries is
reached, the MOSFET will be latched off if the next over-
current fault occurs before the counter reset timer times
out. During startup when power good conditions are not
met, the counter reset timer is disabled. The retry counter
and the counter reset timer for the overcurrent fault are
independent of those for the FET bad fault.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com