| Electronic Components Datasheet Search |
|
6500QL Datasheet(PDF) 2 Page - 3M Electronics |
|
|
|||||||||||||||||||||||||||||
6500QL Datasheet(HTML) 2 Page - 3M Electronics |
|
2 / 46 page ![]() (English) 1 W WARNING This respirator helps protect against certain airborne contaminants. Misuse may result in sickness or death. For correct use, consult supervisor and User Instructions, or call 3M Technical Service in the United States at 1-800-243-4630. In Canada, call 1-800-267-4414. FOREWORD These User Instructions provide information about facepiece use only. Important information is provided in the User Instructions with each of the air filtration systems that are used with 3M™ Rugged Comfort Quick Latch Half Facepiece Reusable Respirators 6501QL, 6502QL and 6503QL. Read all User Instructions and warnings before using. Keep these User Instructions for reference. If you have questions regarding these products, contact 3M Technical Service. In United States: Website: www.3m.com/workersafety Technical Assistance: 1-800-243-4630 In Canada: Website: www.3M.ca/Safety Technical Assistance: 1-800-267-4414 Intended Use The 3M™ Rugged Comfort Quick Latch Half Facepiece Reusable Respirator 6500QL Series (6501QL, 6502QL, 6503QL) are designed to help provide respiratory protection against certain airborne contaminants when used in accordance with all use instructions and limitations and applicable safety and health regulations. The 3M™ Rugged Comfort Quick Latch Half Facepiece Reusable Respirator, 6500QL Series, is not currently approved for use in supplied air configurations. W WARNING Properly selected, used, and maintained respirators help protect against certain contaminants by reducing airborne concentrations below the Occupational Exposure Limit (OEL). It is essential to follow all instructions and government regulations on the use of this product, including wearing the complete respirator system during all times of exposure in order for the product to help protect the wearer. Misuse of respirators may result in overexposure to contaminants and lead to sickness or death. For correct use, consult supervisor and User Instructions, or contact 3M Technical Service. List of Warnings and Cautions within these User Instructions W WARNING Failure to follow these instructions may reduce respirator performance, expose you to contaminants above the OEL, and may result in sickness or death. • To help maintain a good seal between the face and the faceseal, the respirator faceseal must be clear of obstructions at all times. Do not use with beards, facial hair or anything that prevents direct contact between the face and the respirator faceseal. • Do not clean respirator with solvents. Cleaning with solvents may degrade some respirator components and reduce respirator effectiveness. • Inspect all respirator components before each use to ensure proper operating condition. • Do not alter, misuse, or abuse this respirator. W CAUTION Failure to properly dispose of spent cartridges, filters, or respirators contaminated by hazardous materials can result in personal exposures as well as environmental harm. Handling, transportation and disposal of spent cartridges, filters, or respirators must comply with all applicable federal, state, and local laws and regulations. NIOSH Cautions and Limitations for Negative Pressure Usage The following restrictions may apply. See NIOSH Approval Label. A - Not for use in atmospheres containing less than 19.5 percent oxygen. B - Not for use in atmospheres immediately dangerous to life or health. C - Do not exceed maximum use concentrations established by regulatory standards. H - Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs. J - Failure to properly use and maintain this product could result in injury or death. K - The Occupational Safety and Health Administration regulations require gas-proof goggles to be worn with this respirator when used against formaldehyde. L - Follow the manufacturer’s User’s Instructions for changing cartridges, canister and/or filters. M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. Rugged Comfort Quick Latch Half Facepiece Reusable Respirator 6500QL Series 3 User Instructions |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |