| Electronic Components Datasheet Search |
|
DA9130 Datasheet(PDF) 18 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
DA9130 Datasheet(HTML) 18 Page - Renesas Technology Corp |
|
18 / 46 page ![]() DA9130 High-Performance, 10 A, Dual-Phase DC-DC Converter for Mobile and Portable Applications Datasheet Revision 2.1 14-Apr-2022 CFR0011-120-00 18 of 45 © 2022 Renesas Electronics Figure 8: Buck Output Voltage Control Concept 4.1.4 Soft Start-Up and Shutdown To limit in-rush current from VSYS, the buck converter can perform a soft-start after being enabled. The start-up behavior is a compromise between acceptable inrush current from the battery and turn- on time. Ramp times can be configured in register CH1_SR_STARTUP. Rates higher than 20 mV/µs may produce overshoot during the start-up phase, so it should be considered carefully. A ramped power down can be selected in register bits CH1_SR_SHDN. When no ramp is selected (immediate power down), the output node will be discharged only by the pull-down resistor, if enabled in register CH1_PD_DIS. 4.1.5 Current Limit The integrated current limit protects the power stages and external coil from excessive current. The buck current limit should be configured to at least 40 % higher than the required maximum output current. When the current limit is reached, the buck converter generates an event and an interrupt to the host processor unless the interrupt has been masked using register M_OC1 in SYS_MASK_1. Register bit OC_DVC_MASK is used to mask over-current events during DVC transitions. 4.1.6 Thermal Protection DA9130 is protected from internal overheating by thermal shutdown. There are two kinds of flags concerning thermal protection, thermal warning and thermal critical. The warning flag is asserted when TJ > TWARN and the critical flag is asserted when TJ > TCRIT. When the critical flag is asserted, Buck1 is shut down immediately. Table 12: Thermal Protection Control Registers Category Register name Description Status TEMP_WARN Asserted as long as the thermal warning threshold is reached TEMP_CRIT Asserted as long as the thermal shutdown threshold is reached IRQ event E_TEMP_WARN TEMP_WARN caused event E_TEMP_CRIT TEMP_CRIT caused event IRQ mask M_TEMP_WARN TEMP_WARN event IRQ mask M_TEMP_CRIT TEMP_CRIT event IRQ mask |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |