Back Button 8802 Datasheet HTML 26Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 27Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 28Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 29Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 30Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 31Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 32Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 33Page - Christian Bürkert GmbH & Co. KG 8802 Datasheet HTML 34Page - Christian Bürkert GmbH & Co. KG Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 39 page
background image
Type 8025
30 | 39
Visit product website 
Batch controller, compact or remote variants
The device has 2 operating levels:
• the process level
• the configuration level, which includes the parameters, the test, the information and the history menus
Operating level
Functions
Process
This level allows:
• to start a dosing
• to read
– the value of the main totalizer of the quantity of fluid counted
– the value of the daily totalizer of the quantity of fluid counted
– the value of the main totalizer of the performed dosings
– the value of the daily totalizer of the performed dosings
• to reset
– the daily volume or mass totalizer
– the daily totalizer of the performed dosings
• to access to the parameters, test, information and history menus of the configuration level
Configuration -
parameters menu
This level allows:
• to set the required operation parameters
– language
– engineering units (international measuring units)
– K factor/Teach function
– optional/dosing mode
– overfill
– alarm
– outputs
– resetting the 2 volume or mass totalizers
– resetting the 2 totalizers of the performed dosings
– resetting the history menu
– backlight
Configuration - test
menu
This level allows:
• to check
– the inputs functions
– the outputs functions
– the paddle-wheel operation
• to monitor
– the flow rate in the pipe
– the value of the daily volume or mass totalizer
– the number of performed dosings
• to save/ restore
– the current user configuration
– the saved configuration
– the default configuration of the device
Configuration - history
menu
This level allows to consult the quantities dosed in the last 10 dosings
Configuration - informa-
tion menu
This level allows to read the fault and warning messages generated



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com