Back Button HD6432607 Datasheet HTML 441Page - Renesas Technology Corp HD6432607 Datasheet HTML 442Page - Renesas Technology Corp HD6432607 Datasheet HTML 443Page - Renesas Technology Corp HD6432607 Datasheet HTML 444Page - Renesas Technology Corp HD6432607 Datasheet HTML 445Page - Renesas Technology Corp HD6432607 Datasheet HTML 446Page - Renesas Technology Corp HD6432607 Datasheet HTML 447Page - Renesas Technology Corp HD6432607 Datasheet HTML 448Page - Renesas Technology Corp HD6432607 Datasheet HTML 449Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 445 / 710 page
background image
Section 13 Serial Communication Interface (SCI)
Rev. 1.00 Jan. 29, 2008 Page 405 of 666
REJ09B0427-0100
after checking that the SCI has finished transmission, initialize the SCI, and set TE to 0 and RE to
1. Whether SCI has finished transmission or not can be checked with the TEND flag.
13.7.6
Data Transmission (Except for Block Transfer Mode)
As data transmission in smart card interface mode involves error signal sampling and
retransmission processing, the operations are different from those in normal serial communication
interface mode (except for block transfer mode). Figure 13.26 illustrates the retransfer operation
when the SCI is in transmit mode.
1. If an error signal is sent back from the receiving end after transmission of one frame is
complete, the ERS bit in SSR is set to 1. If the RIE bit in SCR is enabled at this time, an ERI
interrupt request is generated. The ERS bit in SSR should be kept cleared to 0 until the next
parity bit is sampled.
2. The TEND bit in SSR is not set for a frame in which an error signal indicating an abnormality
is received. Data is retransferred from TDR to TSR, and retransmitted automatically.
3. If an error signal is not sent back from the receiving end, the ERS bit in SSR is not set.
Transmission of one frame, including a retransfer, is judged to have been completed, and the
TEND bit in SSR is set to 1. If the TIE bit in SCR is enabled at this time, a TXI interrupt
request is generated. Writing transmit data to TDR transfers the next transmit data.
Figure 13.28 shows a flowchart for transmission. The sequence of transmit operations can be
performed automatically by specifying the DTC to be activated with a TXI interrupt source. In a
transmit operation, the TDRE flag is set to 1 at the same time as the TEND flag in SSR is set, and
a TXI interrupt will be generated if the TIE bit in SCR has been set to 1. If the TXI request is
designated beforehand as a DTC activation source, the DTC will be activated by the TXI request,
and transfer of the transmit data will be carried out. The TDRE and TEND flags are automatically
cleared to 0 when data is transferred by the DTC. In the event of an error, the SCI retransmits the
same data automatically. During this period, the TEND flag remains cleared to 0 and the DTC is
not activated. Therefore, the SCI and DTC will automatically transmit the specified number of
bytes in the event of an error, including retransmission. However, the ERS flag is not cleared
automatically when an error occurs, and so the RIE bit should be set to 1 beforehand so that an
ERI request will be generated in the event of an error, and the ERS flag will be cleared.
When performing transfer using the DTC, it is essential to set and enable the DTC before carrying
out SCI setting. For details of the DTC setting procedures, see section 8, Data Transfer Controller
(DTC).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com