Back Button MAX11040 Datasheet HTML 5Page - Maxim Integrated Products MAX11040 Datasheet HTML 6Page - Maxim Integrated Products MAX11040 Datasheet HTML 7Page - Maxim Integrated Products MAX11040 Datasheet HTML 8Page - Maxim Integrated Products MAX11040 Datasheet HTML 9Page - Maxim Integrated Products MAX11040 Datasheet HTML 10Page - Maxim Integrated Products MAX11040 Datasheet HTML 11Page - Maxim Integrated Products MAX11040 Datasheet HTML 12Page - Maxim Integrated Products MAX11040 Datasheet HTML 13Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 31 page
background image
24-Bit, 4-Channel, Simultaneous-Sampling,
Cascadable, Sigma-Delta ADC
_______________________________________________________________________________________
9
Pin Description (continued)
PIN
NAME
FUNCTION
16
SCLK
Serial-Clock Input. Clocks in data at DIN on the falling edge of SCLK and clocks out data at DOUT on the
rising edge of SCLK.
17
DIN
Serial Data Input. Data at DIN is clocked in on the falling edge of SCLK.
18
DOUT
Serial Data Output. The drive for DOUT is enabled by a falling edge on CS while CASCIN is low or by a
falling edge on CASCIN while CS is low. DOUT is disabled/three-stated when CS is high or after the
appropriate number of data bytes have been transferred in response to the requested command. Data is
clocked out at DOUT on the rising edge of SCLK.
19
FAULT
Active-Low Overvoltage Fault Indicator Output. FAULT goes low when any analog input goes outside the fault
threshold range (between VPFT and VNFT). The FAULT output is open drain with a 30k
Ω internal pullup
resistor, allowing wire-NOR functionality. See the Analog Input Overvoltage and Fault Protection section.
20
OVRFLW
Active-Low Channel Data Overflow Output. OVRFLW goes low when a conversion result goes outside the
voltage range bounded by the positive and negative full scale on one or more of the analog input
channels or when FAULT goes low. The OVRFLW output is open drain with a 30k
Ω internal pullup resistor,
allowing wire-NOR functionality. See the Analog Input Overvoltage and Fault Protection section.
21
CLKOUT
Buffered Clock Output. When the XTALEN bit in the configuration register is 1 and a crystal is installed
between XIN and XOUT, CLKOUT provides a buffered version of the internal oscillator’s clock. Setting the
XTALEN bit to 0 places CLKOUT in a high-impedance state.
22
DRDYOUT
Active-Low Data Ready Output. When DRDYIN = 0, DRDYOUT outputs a logic-low to indicate the
availability of a new conversion result. DRDYOUT transitions high at the next CS falling edge or when
DRDYIN = 1. See the Multiple Device Connection section.
23
DRDYIN
Active-Low Data Ready Input. A logic-high at DRDYIN causes DRDYOUT to output a logic-high. When
DRDYIN = 0, DRDYOUT outputs a logic-low when a new conversion result is available. See the Multiple
Device Connection section. Connect DRDYIN to DGND when not daisy chaining multiple devices.
24
SYNC
Sampling Synchronization Input. The falling edge of SYNC aligns sampling and output data so that
multiple devices sample simultaneously. Synchronize multiple devices running from independent crystals
by connecting DRDYOUT of the last device in the chain to the SYNC inputs of all devices in the chain.
Connect SYNC to DGND for single device operation. See the Multiple Device Connection section.
25
XOUT
Crystal Oscillator Output. Connect a 24.576MHz external crystal or resonator between XIN and XOUT
when using the internal oscillator. Leave XOUT unconnected when driving the MAX11040 with an external
frequency. See the Crystal Oscillator section.
26
XIN
Crystal Oscillator/Clock Input. Connect a 24.576MHz external crystal or resonator between XIN and XOUT
when using the internal oscillator or drive XIN with an external clock and leave XOUT unconnected. See
the Crystal Oscillator section.
30
AVDD
Positive Analog Supply Voltage. Bypass to AGND with a 1µF capacitor in parallel with a 0.01µF capacitor
as close as possible to the device.
32
REF3
ADC3 Buffered Reference Voltage. Bypass with a 1µF capacitor to AGND.
33
AIN3+
Positive Analog Input Channel 3
34
AIN3-
Negative Analog Input Channel 3
36
REF2
ADC2 Buffered Reference Voltage. Bypass with a 1µF capacitor to AGND.
37
AIN2+
Positive Analog Input Channel 2
38
AIN2-
Negative Analog Input Channel 2



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com