25 / 30 page ![]() 點晶科技股份有限公司 SILICON TOUCH TECHNOLOGY INC. DM164 8x3-CHANNEL CONSTANT CURRENT LED DRIVERS Version:A.002 Page 24 d) Power-on Reset Suggestion The DM164 doesn’t built-in automatic power-on reset function. In order to make sure the DM164 can work normally after the power-on situation. Users can add an LTH pulse before normal operation, like Figure 15 shows. a. D&G Mode First MSEL DIN DCK (DCKPH=L) D&G[191] LTH 1 192 DCK (DCKPH=H) 1 192 At Least 10 GCK Latencies GD[383] 1 GD Mode 384 1 384 10 GCK Latencies 2 2 2 2 D&G Mode VDD POWER-ON NORMAL OPERATION … … … … GCK … D&G[190] D&G[0] GD[382] GD[0] EN_B b. GD Mode First MSEL DIN DCK (DCKPH=L) GD[383] LTH 1 384 DCK (DCKPH=H) 1 384 At Least 10 GCK Latencies D&G[191] 1 D&G Mode 192 1192 10 GCK Latencies 2 2 2 2 GD Mode VDD POWER-ON NORMAL OPERATION … … … … GCK … GD[382] GD[0] D&G[190] D&G[0] VDD Figure 15. Power-on Reset Suggestion Timing Diagram |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|