| Electronic Components Datasheet Search |
|
VSC056 Datasheet(PDF) 96 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
VSC056 Datasheet(HTML) 96 Page - Maxim Integrated Products |
|
96 / 134 page ![]() 96 of 134 VSC056 Data Sheet Revision 4.1 January 2008 3.2.85 CEh: General-Purpose Timer Count 2 (GPTC2) The following table shows the bit assignments for the General-Purpose Timer Count 2 register. 3.2.86 CFh: General-Purpose Timer Enable (GPTE) The following table shows the bit assignments for the General-Purpose Timer Enable register. Register Name: GPTC2 Address: CEh Reset Value: 0000_0000b Bit Bit Label Access Description 7:0 TC23-16 R/W Timer Count These eight bits are part of the 24-bit general-purpose timer down counter initial count value. Writing to this register causes the timer to update and initiate a countdown from the new value if the timer has been enabled in the GPTE register. Clearing this register, along with the GPTC0 and GPTC1 registers, stops the down counter and disables the interrupt generation logic. After a reset or power on, these bits are cleared. Register Name: GPTE Address: CFh Reset Value: 0000_0000b Bit Bit Label Access Description 7:1 RES R Reserved. 0 GPTE R/W General-Purpose Timer Enable This bit enables the general-purpose timer to down count and generate an interrupt when the timer reaches zero. The general-purpose timer down counts using a clock source that is a divide-by-three of the core clock (8.0 MHz to 12.5 MHz), resulting in a timer count resolution of 375 ns to 240 ns. When the timer initial count is set to all 1s, the maximum timeout is greater than four seconds when using a 12.5 MHz core clock. When the 24-bit timer reaches a value of zero, the interrupt output of the VSC056 is asserted. The timer then re-loads with the initial count value found in the GPTC0, GPTC1, and GPTC2 registers and begins counting down again. Writing a value of FFh to the BCIS register clears this interrupt. After a reset or power on, this bit is cleared, disabling the timer and timer interrupt. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |