| Electronic Components Datasheet Search |
|
WM8351 Datasheet(PDF) 167 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8351 Datasheet(HTML) 167 Page - Wolfson Microelectronics plc |
|
167 / 330 page ![]() Production Data WM8351 w PD, April 2012, Rev 4.5 167 18 SYSTEM MONITORING AND UNDERVOLTAGE LOCKOUT (UVLO) The WM8351 includes several mechanisms to prevent the system from starting up, or force it to shut down, when power sources are critically low. The under-voltage lockout (UVLO) is a non-programmable voltage limit. When the available supplies are below this limit, the WM8351 enters the BACKUP state. The WM8351 can only proceed from BACKUP to the OFF state if LINE is above the UVLO level. Whenever the WM8351 is in ACTIVE, HIBERNATE or OFF state and LINE falls below the UVLO level, the WM8351 returns to the BACKUP state. The UVLO limit threshold is equal to VRTC + 50mV. The precise value of VRTC may vary between devices, within the limits defined in the Electrical Characteristics (see Section 7.5). The startup threshold is a programmable voltage limit. The WM8351 can only proceed from OFF to the ACTIVE state if LINE is above the startup threshold. (Note that, in the case of USB-powered operation, there are additional voltage requirements; see Section 17.4.). The startup threshold is determined by the PCCMP_ON_THR register field. The shutdown threshold is determined by the PCCMP_OFF_THR register field. When LINE falls below this threshold, the WM8351 raises a SYS_HYST_COMP_FAIL_EINT interrupt. In addition, the WM8351 takes the action set by PCCOMP_ERRACT. If this bit is set, then the WM8351 will shut down in response to the LINE voltage falling below the shutdown threshold. The startup and shutdown control register fields are described in Table 112. Note that the startup threshold should always be set higher than the shutdown threshold in order to create a hysteresis, making the system more stable. The SYS_HYST_COMP_FAIL_EINT interrupt is one of the second-level interrupts which triggers a first-level System Interrupt, SYS_INT (see Section 24). This can be masked by setting the mask bit as described in Table 113. ADDRESS BIT LABEL DEFAULT DESCRIPTION R179 (B3h) Power Check Comparator 14 PCCMP_ER RACT 0 Action to take when LINE falls below PCCMP_OFF_THR level (as well as generating an interrupt) 0 = ignore 1 = shut down system 6:4 PCCMP_OF F_THR [2:0] 010 Power check comparator system shutdown threshold value 000 = 2.9V 001 = 3.0V … 111 = 3.6V Protected by security key. 2:0 PCCMP_ON _THR [2:0] 101 Power check comparator system startup threshold value 000 = 2.9V 001 = 3.0V … 111 = 3.6V Protected by security key. Table 112 Battery Monitoring and UVLO Control |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |