292 / 336 page ![]() WM8352 Production Data w PD, February 2011, Rev 4.4 292 REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION REFER TO Reset by state machine. Default held in metal mask. 2 DC3_ENA 0 DCDC3 converter enable 0 = disabled 1 = enabled Note: internal conditions may prevent the converter from actually switching on - see DCDC/LDO Status register for actual converter status. Reset by state machine. Default held in metal mask. 1 DC2_ENA 0 DCDC2 converter enable 0 = disabled 1 = enabled Note: internal conditions may prevent the converter from actually switching on - see DCDC/LDO Status register for actual converter status. Reset by state machine. Default held in metal mask. 0 DC1_ENA 0 DCDC1 converter enable 0 = disabled 1 = enabled Note: internal conditions may prevent the converter from actually switching on - see DCDC/LDO Status register for actual converter status. Reset by state machine. Default held in metal mask. Register B0h DCDC/LDO requested REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION REFER TO R177 (B1h) DCDC Active options 15 DCDC_DISCLKS 0 DCDC clock enable 0 = DCDC Clocks enabled 1 = DCDC1, 3, 4 and 6 clocks disabled. Note: This feature is useful in reducing the current consumption if all 4 DCDCs are in LDO mode. The requirement is to put them in LDO mode and then at least 100us is required before clocks are disabled. Again while coming out of LDO mode first enable the clocks and then at least 100us wait and then come out of LDO mode. This can only be used if the processor is alive to set and unset this bit. Reset by state machine. 13:12 PUTO[1:0] 00 Power up time out value for all converters 00 = 0.5ms 01 = 2ms 10 = 32ms 11 = 256ms Reset by state machine. 5 DC6_ACTIVE 1 DC-DC 6 Active mode 0 = Select Standby mode 1 = Select Active mode Reset by state machine. 3 DC4_ACTIVE 1 DC-DC 4 Active mode 0 = Select Standby mode 1 = Select Active mode Reset by state machine. 2 DC3_ACTIVE 1 DC-DC 3 Active mode 0 = Select Standby mode 1 = Select Active mode |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |