Back Button TAS5760LD Datasheet HTML 20Page - Texas Instruments TAS5760LD Datasheet HTML 21Page - Texas Instruments TAS5760LD Datasheet HTML 22Page - Texas Instruments TAS5760LD Datasheet HTML 23Page - Texas Instruments TAS5760LD Datasheet HTML 24Page - Texas Instruments TAS5760LD Datasheet HTML 25Page - Texas Instruments TAS5760LD Datasheet HTML 26Page - Texas Instruments TAS5760LD Datasheet HTML 27Page - Texas Instruments TAS5760LD Datasheet HTML 28Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 54 page
background image
TAS5760LD
SLOS781 – JULY 2013
www.ti.com
Speaker Amplifier Fault Notification (SPK_FAULT Pin)
In both hardware and Software Control mode, the SPK_FAULT pin of the TAS5760LD serves as a fault indicator
to notify the system that a fault has occurred with the speaker amplifier by being actively pulled "LOW". This pin
is an open drain output pin and, unless one is provided internal to the receiver, requires an external pull-up to set
the net to a known value. The behavior of this pin varies based upon the type of error which has occurred.
In the case of a latching error, the fault line will remain "LOW" until such time that the TAS5760LD has resumed
normal operation (that is the SPK_SD pin has been toggled and TSPK_FAULT has passed).
With the exception of clock errors, non-latching errors will not cause the SPK_FAULT pin to be pulled "LOW".
Once a non-latching error has been cleared, normal operation will resume. For clocking errors, the SPK_FAULT
line will be pulled "LOW", but upon clearing of the clock error normal operation will resume automatically, i.e. with
no TSPK_FAULT delay.
One method which can be used to convert a latching error into an auto-recovered, non-latching error is to
connect the SPK_FAULT pin to the SPK_SD pin. In this way, a fault condition will automatically toggle the
SPK_SD pin when the SPK_FAULT pin goes "LOW" and returns "HIGH" after the TSPK_FAULT period has passed.
Table 1. Protection Suite Error Handling Summary
Error
Cause
Fault Type
Error is cleared by:
Non-Latching
Over Voltage Error
PVDD level rises above that specified by
(SPK_FAULT
PVDD level returning below OVETHRES(PVDD)
(OVE)
OVERTHRES(PVDD)
Pin is not pulled
"LOW")
Non-Latching
Under Voltage Error
PVDD voltage level drops below that
(SPK_FAULT
PVDD level returning above UVETHRES(PVDD)
(UVE)
specified by UVEFTHRES(SPK)
Pin is not pulled
"LOW")
One or more of the following errors has
occured:
Non-Latching
1.
Non-Supported
MCLK
to
LRCK
Clock Error
(SPK_FAULT
Clocks returning to valid state
and/or SCLK to LRCK Ratio
(CLKE)
Pin is pulled
"LOW")
2.
Non-Supported MCLK or LRCK rate
3.
MCLK, SCLK, or LRCK has stopped
Speaker Amplifier output current has
Over-Current Error
TSPK_FAULT has passed AND SPK_SD Pin or Bit
increased above the level specified by
Latching
(OCE)
Toggle
OCETHRES
DC offset voltage on the speaker
DC Detect Error
TSPK_FAULT has passed AND SPK_SD Pin or Bit
amplifier output has increased above the
Latching
(DCE)
Toggle
level specified by the DCETHRES
TSPK_FAULT has passed AND SPK_SD Pin or Bit
The temperature of the die has increased
Over-Temperature Error
Toggle AND the temperature of the device has
above the level specified by the
Latching
(OTE)
reached a level below that which is dictated by the
OTETHRES
OTEHYST specification
DC DETECT PROTECTION
The TAS5760LD has circuitry which will protect the speakers from DC current which might occur due to an
internal amplifier error. The device behavior in response to a DCE event is detailed in the table in the previous
section.
A DCE event occurs when the output differential duty-cycle of either channel exceeds 60% for more than 420
msec at the same polarity. The table below shows some examples of the typical DCE Protection threshold for
several values of the supply voltage. This feature protects the speaker from large DC currents or AC currents
less than 2Hz.
The minimum output offset voltages required to trigger the DC detect are show in Table 2. The outputs must
remain at or above the voltage listed in the table for more than 420 msec to trigger the DC detect.
24
Copyright © 2013, Texas Instruments Incorporated
Product Folder Links: TAS5760LD



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com