56 / 149 page ![]() AS3911 – 56 ams Datasheet, Confidential: 2013-Oct [2-03] A p pl i c at io n I n f o r m at i o n manual gain reduction from Receiver Configuration Register 4. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is possible. IRQ due to termination of direct command is not produced. Adjust Regulators When this command is sent the power supply level of VDD is measured in maximum load conditions and the regulated voltage reference is set 250 mV below this measured level to assure maximum possible stable regulated supply (See “Power Supply System” on page 34.). Using this command increases the system PSSR. At the beginning of execution of this command, both the receiver and transmitter are switched on to have the maximum current consumption, the regulators are set to the maximum regulated voltage (5.1 V in case of 5 V supply and 3.4 V in case of 3.3 V supply mode). After 300 μs VSP_RF is compared to VDD, in case VSP_RF is not at least 250 mV lower the regulator setting is reduced for one step (120 mV in case of 5 V supply and 100 mV in case of 3.3 V supply mode) and measurement is done after next 300 μs. Procedure is repeated until VSP_RF drops at least 250 mV below VDD or until minimum regulated voltage (3.9 V in case of 5 V supply and 2.4 V in case of 3.3 V supply mode) is reached. Duration time: 5 ms max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. This command is not accepted in case the external definition of the regulated voltage is selected in the Regulator Voltage Control Register (bit reg_s is set to H) Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Calibrate Modulation Depth Starts a patent pending sequence, which activates the transmission, measures the modulation depth and adapts it to comply with the modulation depth specified in the AM Modulation Depth Control Register. When calibration procedure is finished result is displayed in the AM Modulation Depth Display Register. Please refer to See “AM Modulation Depth: Definition and Calibration” on page 132. for details about setting the AM modulation depth and running this command. Duration time: 275μs max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is not possible. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |