19 / 42 page ![]() ams Datasheet Page 19 [v1-01] 2016-Feb-17 Document Feedback AS5171 − Register Description Figure 22: Output Transfer Function The breakpoint BP sets the discontinuity point where the output jumps from one clamping level to the other. It is strongly recommended to set the breakpoint at the maximum distance from the start and stop position (T1 and T2). To handle the case of a full turn, a hysteresis function across the breakpoint can be used to avoid sudden jumps between the lower and upper clamping level. Figure 23: Hysteresis Setting The hysteresis LSB is based on the core resolution (14-bit). HYST Hysteresis LSBs 00 0 01 56 10 91 11 137 Upper failure band Lower failure band Max out CLMPH CLMPL OT2 OT1 T1 T2 BGPD BVPU Upper clamping band Lower clamping band BP Electrical range Mechanical range Mechanical angle Measured angle |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|