| Electronic Components Datasheet Search |
|
GS3241 Datasheet(PDF) 36 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
GS3241 Datasheet(HTML) 36 Page - Semtech Corporation |
|
36 / 108 page ![]() GS3241 Final Data Sheet Rev.2 PDS-061444 September 2017 36 of 108 Semtech Proprietary & Confidential www.semtech.com 4.6 PRBS Generator The GS3241 includes an integrated PRBS generator which can produce a differential PRBS7 or a divided clock signal on either output for system testing. Note: When working with the PRBS Generator, please note the following. • The PRBS generator and checker can be active at the same time, however, the generator can not be looped back on itself for error checking. • If the application requires adjustments to the default output swing, please see Section 4.7.4. • The parameters referred to within this section are linked to their respective registers in Table 4-7. For a complete list of registers and functions, please see Section 5. 1. Select the PRBS generator as the source on the appropriate output: To switch DDO0/DDO0 from data mode to PRBS generator mode, set CTRL_OUTPUT0_SIGNAL_SEL = 1 To switch DDO1/DDO1 from data mode to PRBS generator mode, set CTRL_OUTPUT1_SIGNAL_SEL = 1 2. The default device settings are configured to power down the device on loss of input signal. If the PRBS generator is to be used without a valid input signal, then the following automatic setting parameters must be disabled. This must be done to ensure device is powered up and the outputs are active for the PRBS generator. The following settings are required for PRBS generator on either output: CTRL_AUTO_SLEEP = 0 CTRL_MANUAL_SLEEP = 0 The following settings are required when DDO1/DDO1 is selected as PRBS output: CTRL_OUTPUT1_AUTO_MUTE = 0 CTRL_OUTPUT1_MANUAL_MUTE = 0 CTRL_OUTPUT1_AUTO_DISABLE = 0 CTRL_OUTPUT1_MANUAL_DISABLE = 0 The following settings are required when DDO0/DDO0 is selected as PRBS output: CTRL_OUTPUT0_AUTO_MUTE = 0 CTRL_OUTPUT0_MANUAL_MUTE = 0 CTRL_OUTPUT0_AUTO_DISABLE = 0 CTRL_OUTPUT0_MANUAL_DISABLE = 0 3. Set the values within the following parameters which meet the needs of the application: CTRL_PRBS_GEN_SIGNAL_SELECT CTRL_PRBS_GEN_CLK_SRC CTRL_PRBS_GEN_DATA_RATE |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |