61 / 108 page ![]() GS3241 Final Data Sheet Rev.2 PDS-061444 September 2017 61 of 108 Semtech Proprietary & Confidential www.semtech.com 4.9.10 Default GSPI Operation By default at power up or after a device reset, the GS3241 is set for Loop-Through Operation and the internal DEV_UNIT_ADDRESS field of the device is set to 0. Figure 4-36 shows a functional block diagram of the Configuration and Status Register (CSR) map in the GS3241. Figure 4-36: Internal Register Map Functional Block Diagram The steps required for the application host processor to write to the Configuration and Status Registers via the GSPI, are as follows: 1. Set Command Word 1 for write access (R/W = 0); set Auto Increment; set the Unit Address field in the Command Word 1 to match the configured DEV_UNIT_ADDRESS which will be zero after power-up. Set the Register Address bits in Command Word 1 to match the upper 7 bits of the register address to be accessed. Set the bits in Command Word 2 to match the lower 16 bits of the register address to be accessed. Write Command Word 1 and Command Word 2. 2. Write the Data Word to be written to the first register. 3. Write the Data Word to be written to the next register in Auto Increment mode, etc. Read access is the same as the above with the exception of step 1, where the Command Word 1 is set for read access (R/W = 1). Note: The UNIT ADDRESS field of Command Word 1 must always match DEV_UNIT_ADDRESS for an access to be accepted by the device. Changing DEV_UNIT_ADDRESS to a value other than 0 is only required if multiple devices are connected to a single chip select (in Loop-Through or Bus-Through configuration). Reg 0 Compare Configuration and Status Registers Read/Write Data to be written / Read Data DATA [15:0] DEV_UNIT_ADDRESS GSPI_LINK _DISABLE GSPI_BUS_ THROUGH _ENABLE RESERVED bits [4:0] [13] [14] [15] bits RESERVED [12:5] Lower 16 bits of Register Address COMMAND 2 [15:0] bits [12] [6:0] COMMAND 1 At power-up or after a device reset, DEV_UNIT_ADDRESS = 00 h [11:7] [13] [14] bits Register Address Upper 7 bits R/W Unit Address 32 devices BCAST ALL Auto Inc EMEM [15] |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |