39 / 138 page ![]() LTM4664A 39 Rev. 0 For more information www.analog.com UV threshold is exceeded for each output. It is possible to feed the PGOOD_Cn pin from one LTM4664A PSM channel into the RUN_Cn pin of the next LTM4664A PSM channel in the sequence, especially across multi- ple LTM4664As. The PGOOD_Cn has a 60µs filter. If the VOUT voltage bounces around the UV threshold for a long period of time it is possible for the PGOOD_Cn output to toggle more than once. To minimize this problem, set the TON_RISE time under 100ms. If a fault in the string of rails is detected, only the faulted rail and downstream rails will fault off. The rails in the string of devices in front of the faulted rail will remain on unless commanded off. There are two ways to respond to faults; which are retry mode and latched off mode. In retry mode, the controller responds to a fault by shutting down and entering the inac- tive state for a programmable delay time (MFR_RETRY_ DELAY). This delay minimizes the duty cycle associated with autonomous retries if the fault that causes the shut- down disappears once the output is disabled. The retry delay time is determined by the longer of the MFR_RETRY_ DELAY command or the time required for the regulated output to decay below 12.5% of the programmed value. If multiple outputs are controlled by the same FAULT_Cn pin, the decay time of the faulted output determines the retry delay. If the natural decay time of the output is too long, it is possible to remove the voltage requirement of the MFR_RETRY_DELAY command by asserting bit 0 of MFR_CHAN_CONFIG. Alternatively, latched off mode means the controller remains latched-off following a fault and clearing requires user intervention such as toggling RUN_Cn or commanding the part OFF then ON. LIGHT-LOAD CURRENT OPERATION The LTM4664A PSM Regulators have two modes of oper- ation: high efficiency discontinuous conduction mode or forced continuous conduction mode. Mode selection is done using the MFR_PWM _MODE command (discon- tinuous conduction is always the start-up mode, forced continuous is the default running mode). If a controller is enabled for discontinuous operation, the inductor current is not allowed to reverse. The reverse current comparator’s output turns off the bottom MOSFET just before the inductor current reaches zero, preventing it from reversing and going negative. In forced continuous operation, the inductor current is allowed to reverse at light loads or under large transient conditions. The peak inductor current is determined solely by the voltage on the COMP_Cn pins. In this mode, the efficiency at light loads is lower than in discontinuous mode operation. However, continuous mode exhibits lower output ripple and less interference with audio cir- cuitry, but may result in reverse inductor current, which can cause the input supply to boost. The VIN_OV_FAULT_ LIMIT can detect this and turn off the offending channel. However, this fault is based on an ADC read and can take Figure 8. Event (Voltage) Based Sequencing LTM4664A RUN_C1 RUN_C0 PGOOD_C0 PGOOD_C1 PGOOD_C0 PGOOD_C1 START LTM4664A 4664A F08 RUN_C0 TO NEXT CHANNEL IN THE SEQUENCE RUN_C1 SHUTDOWN The LTM4664A PSM Regulators supports two shutdown modes. The first mode is closed-loop shutdown response, with user defined turn-off delay (TOFF_DELAY) and ramp down rate (TOFF_FALL). The controller will maintain the mode of operation for TOFF_FALL. The second mode is dis- continuous conduction mode, the controller will not draw current from the load and the fall time will be set by the output capacitance and load current, instead of TOFF_FALL. The shutdown occurs in response to a fault condition or loss of SHARE_CLK (if bit 2 of MFR_CHAN_ CONFIG is set to a 1) or VIN falling below the VIN_OFF thresh- old or FAULT pulled low externally (if the MFR_FAULT_ RESPONSE is set to inhibit). Under these conditions, the power stage is disabled in order to stop the transfer of energy to the load as quickly as possible. The shutdown state can be entered from the soft-start or active regula- tion states or through user intervention. DUAL 25A/30A PSM OPERATION |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |