| Electronic Components Datasheet Search |
|
TAS5036B Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TAS5036B Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 56 page ![]() Architecture Overview 15 SLES073—February 2003 TAS5036B 2.2 Reset, Power Down, and Status The reset, power down, and status circuitry provides the necessary controls to bring the TAS5036B to the initial inactive condition, achieve low power standby, and report system status. 2.2.1 Reset—RESET The TAS5036B is placed in the reset mode by setting the RESET terminal low. RESET is an asynchronous control signal that restores the TAS5036B to its default conditions, sets the valid 1–6 outputs low, and places the PWM in the hard mute state. Volume is immediately set to full attenuation (there is no ramp down). As long as the RESET terminal is held low, the device is in the reset state. During reset, all I2C and serial data bus operations are ignored. Table 2–6 shows the device output signals while RESET is active. Upon the release of RESET, if POWER_DWN is high, the system performs a 4-ms to 5-ms device initialization and then ramps the volume up to 0 db using a soft volume update sequence. If MCLK_IN is not active when RESET is released high, then a 4-ms to 5-ms initialization sequence is produced once MCLK_IN becomes active. During device initialization all controls are reset to their initial states. Table 2–7 shows the control settings that are changed during initialization. RESET should be applied during power-up initialization or while changing the master slave clock states. Table 2–6. Device Outputs During Reset SIGNAL MODE SIGNAL STATE Valid 1–Valid 6 All Low PWM P-outputs All Low PWM M-outputs All Low MCLKOUT All Low SCLK Master Low SCLK Slave Signal input LRCLK Master Low LRCLK Slave Signal input SDA All Signal input CLIP All High Because the RESET is an asynchronous control signal, small clicks and pops can be produced during the application (the leading edge) of this control. However, when RESET is released, the transition from the hard mute state back to normal operation is performed synchronously using a quiet sequence. If a completely quiet reset sequence is desired, MUTE should be applied before applying RESET. Table 2–7. Values Set During Reset CONTROL SETTING Volume 0 dB MCLK_IN frequency 256 Master/slave mode M_S terminal state Automute Enabled De-emphasis None DC offset 0 Interchannel delay Each channel is set to default value |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |