Back Button ADS1291IRSMT Datasheet HTML 37Page - Texas Instruments ADS1291IRSMT Datasheet HTML 38Page - Texas Instruments ADS1291IRSMT Datasheet HTML 39Page - Texas Instruments ADS1291IRSMT Datasheet HTML 40Page - Texas Instruments ADS1291IRSMT Datasheet HTML 41Page - Texas Instruments ADS1291IRSMT Datasheet HTML 42Page - Texas Instruments ADS1291IRSMT Datasheet HTML 43Page - Texas Instruments ADS1291IRSMT Datasheet HTML 44Page - Texas Instruments ADS1291IRSMT Datasheet HTML 45Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 41 / 83 page
background image
t
<
SCLK
t
4 t
DR
CLK
-
72 (2 x 24 bits +STATUS)
41
ADS1291, ADS1292, ADS1292R
www.ti.com
SBAS502C – DECEMBER 2011 – REVISED APRIL 2020
Product Folder Links: ADS1291 ADS1292 ADS1292R
Submit Documentation Feedback
Copyright © 2011–2020, Texas Instruments Incorporated
8.4 Device Functional Modes
The ADS1291, ADS1292, and ADS1292R can be used in different functional modes, as a single device in a
system, or as multiple devices in a system. The ADS1291, ADS1292, and ADS1292R are designed to provide
configuration flexibility when multiple devices are used in a system, as explained in the Multiple Device
Configuration section.
In terms of data conversion, the device can operate in continuous mode as explained in the Continuous mode
section, or in single-shot mode as explained in the Single-shot mode section.
8.5 Programming
8.5.1 SPI Interface
The SPI-compatible serial interface consists of four signals: CS, SCLK, DIN, and DOUT. The interface reads
conversion data, reads and writes registers, and controls ADS1291, ADS1292, and ADS1292R operation. The
DRDY output is used as a status signal to indicate when data are ready. DRDY goes low when new data are
available.
8.5.1.1 Chip Select (CS)
CS selects the ADS1291, ADS1292, and ADS1292R for SPI communication. CS must remain low for the entire
duration of the serial communication. After the serial communication is finished, always wait four or more tCLK
cycles before taking CS high. When CS is taken high, the serial interface is reset, SCLK and DIN are ignored,
and DOUT enters a high-impedance state. DRDY asserts when data conversion is complete, regardless of
whether CS is high or low.
8.5.1.2 Serial Clock (SCLK)
SCLK is the serial peripheral interface (SPI) serial clock. SCLK is used to shift commands in and shift data out
from the device. The serial clock features a Schmitt-triggered input and clocks data on the DIN and DOUT pins
into and out of the ADS1291, ADS1292, and ADS1292R. Even though the input has hysteresis, it is
recommended to keep SCLK as clean as possible to prevent glitches from accidentally forcing a clock event. The
absolute maximum SCLK limit is specified in the Serial Interface Timing table. When shifting in commands with
SCLK, make sure that the entire set of SCLKs is issued to the device. Failure to do so could result in the device
serial interface being placed into an unknown state, requiring CS to be taken high to recover.
For a single device, the minimum speed needed for the SCLK depends on the number of channels, number of
bits of resolution, and output data rate. (For multiple cascaded devices, see the Cascade Mode subsection of the
Multiple Device Configuration section.) The minimum speed can be calculated with Equation 9.
(9)
For example, if the ADS1292R is used in a 500-SPS mode (2 channels, 24-bit resolution), the minimum SCLK
speed is approximately 36 kHz.
Data retrieval can be done either by putting the device in RDATAC mode or by issuing a RDATA command for
data on demand. The above SCLK rate limitation applies to RDATAC. For the RDATA command, the limitation
applies if data must be read in between two consecutive DRDY signals. Equation 9 assumes that there are no
other commands issued in between data captures. SCLK can only be twice the speed of fCLK during register
reads and writes. For faster SPI interface, use fCLK = 2.048 MHz and set the CLK_DIV register bit (in the
LOFF_STAT register) to '1'.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com