ADS1291IRSMT Datasheet(PDF) 65 Page - Texas Instruments

Part # ADS1291IRSMT
Description  ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements
PDF  83 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI2 [Texas Instruments]
Direct Link  https://www.ti.com
Logo TI2 - Texas Instruments

ADS1291IRSMT Datasheet(HTML) 65 Page - Texas Instruments

Back Button ADS1291IRSMT Datasheet HTML 61Page - Texas Instruments ADS1291IRSMT Datasheet HTML 62Page - Texas Instruments ADS1291IRSMT Datasheet HTML 63Page - Texas Instruments ADS1291IRSMT Datasheet HTML 64Page - Texas Instruments ADS1291IRSMT Datasheet HTML 65Page - Texas Instruments ADS1291IRSMT Datasheet HTML 66Page - Texas Instruments ADS1291IRSMT Datasheet HTML 67Page - Texas Instruments ADS1291IRSMT Datasheet HTML 68Page - Texas Instruments ADS1291IRSMT Datasheet HTML 69Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 65 / 83 page
background image
Power Supplies
RESET
t
RST
StartUsingtheDevice
t
POR
18t
CLK
65
ADS1291, ADS1292, ADS1292R
www.ti.com
SBAS502C – DECEMBER 2011 – REVISED APRIL 2020
Product Folder Links: ADS1291 ADS1292 ADS1292R
Submit Documentation Feedback
Copyright © 2011–2020, Texas Instruments Incorporated
10 Power Supply Recommendations
The nominal performance of the device is specified with an analog supply voltage AVDD of 3 V and an internal
reference voltage VREFP of 2.42 V. The device also operates using power supplies at the AVDD pin from 2.7 V
to 5.5 V with excellent performance. Parameters that can vary significantly with operating voltage and reference
voltage are listed in the Typical Characteristics section.
10.1 Power-Up Sequencing
Before device power-up, all digital and analog inputs must be low. At the time of power-up, all of these signals
should remain low until the power supplies have stabilized, as shown in Figure 72. At this time, begin supplying
the master clock signal to the CLK pin. Wait for time tPOR, then transmit a RESET pulse. After releasing RESET,
the configuration register must be programmed, see the CONFIG1: Configuration Register 1 subsection of the
Register Map section for details. The power-up sequence timing is shown in Table 29.
Figure 72. Power-Up Timing Diagram
Table 29. Power-Up Sequence Timing
PARAMETER
MIN
TYP
MAX
UNIT
tPOR
Wait after power-up until reset
212
tMOD
tRST
Reset low width
1
tMOD



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com