54 / 77 page ![]() Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 14 OUTE Outputs enable control bit. Assuming that the FSINB pin is high, if this bit is reset, all the gate drivers are disabled and the MOSFTEs are passively shut down through the internal resistance connected between gate and source. Assuming that the FSINB pin is high, if this bit is set, all the gate drivers are enabled and the MOSFETs are turned on/off according to Table 2 or Table 3 depending on the INPMODE control bit value. Assuming the device in active mode, when the FSINB pin goes low, the MOSFETs gate drivers are forced in sink switch mode and the OUTE control bit is reset. While the FSINB pin is low, the OUTE control bit value is frozen and cannot be changed via SPI. When a watchdog fault occurs, setting the WDGF flag, the OUTE control bit is reset. While the WDGF flag is set, the OUTE control bit value is frozen and cannot be changed via SPI. 13 AFWE Active free-wheeling enable control bit. In case INPMODE is reset, this bit enables/disables active free-wheeling. When set it enables the active free-wheeling. When reset it disables the active free-wheeling. In case INPMODE is set, this bit has no effect. 12 FWS Free-wheeling selection control bit. In case INPMODE is reset and active free-wheeling is enabled (AFWE=1), this bit sets whether the active free-wheeling is performed on high side (FWS=1) or on low-side (FWS=0). In case INPMODE is reset and active free-wheeling is disabled (AFWE=0), this bit sets whether the passive free-wheeling is performed on high side (FWS=1) or on low-side (FWS=0).In case INPMODE is set, this bit has no effect. 11 DIS1 Disable leg1,2 control bits. In case INPMODE is set, these bits switch-off both the external MOSFETs of leg 1 (DIS1=1) and/or leg 2 (DIS2=1). In case INPMODE is reset, these bits have no effect. 10 DIS2 9 DSMON_CONFIG DSMonitoring configuration control bit. In case this bit is set and INPMODE is reset, any VDS monitoring fault will actively switch off all the full-bridge MOSFETs by configuring all the gate drivers in sink switch mode. In all the other cases INPMODE=1 or INPMODE=0 with DSMON_CONFIG=0 just the affected/offended half-bridge MOSFETs are actively switched off configuring the corresponding gate drivers in sink switch mode. 8 OLH1L2 Open load in off-state control bit. This bit is really taken into account only when OUTE is reset, otherwise it is discarded (and related circuitry is disconnected from device power outputs). See Table 4. Full-bridge monitoring in off-mode. 1. The INPMODE will be a read only or a read and write control bit depending on the value of the control bit OUTE. 2. The OUTE is a read only or a read and write control bit depending on the logic level at the input pin FSINB and on the status flag WDGF value. Table 49. Control register DCR (0x03) LSB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 (R/W) 0 (R/W) 0 (R/W) 0 (R/W) 0 (R/W) 0 (R) 0 (R) OLH2L1 OLTHH CP_LOW_CONFIG CPFDD OVTS RES RES P Open load in off-state bit Off-state diagnostic comparator threshold selection bit Charge pump low configuration bit Charge pump frequency dithering disable bit Overvoltage threshold selection bit Reserved bit Reserved bit Parity Bit Name Description 7 OLH2L1 Open load in off-state control bit. This bit is really taken into account only when OUTE is reset, otherwise it is discarded (and related circuitry is disconnected from device power outputs). See Table 4. Full-bridge monitoring in off-modering in off-mode 6 OLTHH Off-state diagnostic comparator threshold selection bit. The off-state diagnostic comparator threshold is set to 1/6VDH for OLTHH reset and to 5/6VDH for OLTHH set. See Table 4. Full- bridge monitoring in off-mode 5 CP_LOW_CONFIG Charge pump low configuration control bit. Setting this bit, CPLOW status flag/bit behaves as a read only status bit and the outputs are re-activated automatically upon recovery of the charge pump output voltage. If this bit is reset, CPLOW status flag/bit behaves as a read & clear status flag so that the outputs are disabled until the CPLOW status flag is cleared. In this latter case, the charge pump output voltage has to rise above VCP_low for a time longer than the corresponding filtering time and CPLOW status flag has to be reset to re-enable device outputs. L99H92 Control registers DS14069 - Rev 4 page 54/77 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |