4518 Datasheet(PDF) 40 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
4518 Datasheet(HTML) 40 Page - Renesas Technology Corp |
|
40 / 160 page ![]() Rev.3.01 2005.06.15 page 40 of 157 REJ03B0008-0301 4518 Group (13) Timer interrupt request flags (T1F, T2F, T3F, T4F) Each timer interrupt request flag is set to “1” when each timer underflows. The state of these flags can be examined with the skip instructions (SNZT1, SNZT2, SNZT3, SNZT4). Use the interrupt control register V1, V2 to select an interrupt or a skip instruction. An interrupt request flag is cleared to “0” when an interrupt occurs or when the next instruction is skipped with a skip instruction. The timer 1 interrupt request flag (T1F) is not set by the timer 1 under- flow signal, it is the flag for detecting the completion of period measurement. (14) Precautions Note the following for the use of timers. • Prescaler Stop counting and then execute the TABPS instruction to read from prescaler data. Stop counting and then execute the TPSAB instruction to set prescaler data. • Timer count source Stop timer 1, 2, 3 and 4 counting to change its count source. • Reading the count value Stop timer 1, 2, 3 or 4 counting and then execute the data read instruction (TAB1, TAB2, TAB3, TAB4) to read its data. • Writing to the timer Stop timer 1, 2, 3 or 4 counting and then execute the data write instruction (T1AB, T2AB, T3AB, T4AB) to write its data. • Writing to reload register R1, R3, R4H When writing data to reload register R1, reload register R3 or re- load register R4H while timer 1, timer 3 or timer 4 is operating, avoid a timing when timer 1, timer 3 or timer 4 underflows. • Timer 4 Avoid a timing when timer 4 underflows to stop timer 4 at the use of PWM output function. When “H” interval extension function of the PWM signal is set to be “valid”, set “1” or more to reload register R4H. • Period measurement function When a period measurement circuit is used, clear bit 0 of regis- ter I1 to “0”, and set a timer 1 count start synchronous circuit to be “not selected”. Start timer operation immediately after operation of a period measurement circuit is started. When the target edge for measurement is input until timer opera- tion is started from the operation of period measurement circuit is started, the count operation is not executed until the timer opera- tion becomes valid. Accordingly, be careful of count data. When data is read from timer, stop the timer and clear bit 2 of register W5 to “0” to stop the period measurement circuit, and then execute the data read instruction. Depending on the state of timer 1, the timer 1 interrupt request flag (T1F) may be set to “1” when the period measurement cir- cuit is stopped by clearing bit 2 of register W5 to “0”. In order to avoid the occurrence of an unexpected interrupt, clear the bit 2 of register V1 to “0” (refer to Figure 28➀) and then, stop the bit 2 of register W5 to “0” to stop the period measurement circuit. In addition, execute the SNZT1 instruction to clear the T1F flag after executing at least one instruction (refer to Figure 28➁). Also, set the NOP instruction for the case when a skip is per- formed with the SNZT1 instruction (refer to Figure 28➂). LA 0 ; (✕0✕✕2) TV1A ; The SNZT1 instruction is valid ........ ➀ LA 0 ; (✕0✕✕2) TW5A ; Period measurement circuit stop NOP ........................................................... ➁ SNZT1 ; The SNZT1 instruction is executed (T1F flag cleared) NOP ........................................................... ➂ ✕ : these bits are not used here. Fig. 28 Period measurement circuit program example While a period measurement circuit is operating, the timer 1 in- terrupt request flag (T1F) is not set by the timer 1 underflow signal, it is the flag for detecting the completion of period mea- surement. When a period measurement circuit is used, select the suffi- ciently higher-speed frequency than the signal for measurement for the count source of a timer 1. When the target signal for period measurement is D6/CNTR0 pin input, do not select D6/CNTR0 pin input as timer 1 count source. (The XIN input is recommended as timer 1 count source at the time of period measurement circuit use.) When the input of P30/INT0 pin is selected for measurement, set the bit 3 of a register I1 to “1”, and set the input of INT0 pin to be enabled. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |