216 / 904 page ![]() Section 4 Exception Handling Rev.1.50 Aug. 30, 2006 Page 176 of 860 REJ09B0288-0150 SPC Saved by Exception in Repeat Control Period: If an exception is accepted in the repeat control period while the repeat counter (RC[11:0]) in the SR register is two or greater, the program counter to be saved may not indicate the value to be returned correctly. To execute the repeat control after returning from an exception processing, the return address must indicate an instruction prior to a repeat detection instruction. Accordingly, if an exception is accepted in repeat control period, an exception other than re-execution type exception by a repeat detection instruction cannot return to the repeat control correctly. Table 4.3 SPC Value when Re-Execution Type Exception Occurs in Repeat Control (RC[11:0] ≥ 2) Number of Instructions in Repeat Loop Instruction where Exception Occurs 1 2 3 4 or Greater RptDtct RptDtct RptDtct RptDtct RptDtct RptDtct1 RptDtct1 RptDtct1 RptDtct1 RptDtct1 RptDtct2 RptDtct1 RptDtct1 RS-4 RptDtct3 RptDtct1 RS-2 Note: The following labels are used here. RptDtct: Repeat detection instruction address RptDtct1: An instruction address one instruction following the repeat detection instruction RptDtct2: An instruction address two instruction following the repeat detection instruction RptDtct3: An instruction address three instruction following the repeat detection instruction RS: Repeat start instruction address If a re-execution type exception is accepted at an instruction in the hatched areas above, a return address to be saved in the SPC is incorrect. If RC[11:0] is 1 or 0, a correct return address is saved in the SPC. Illegal Instruction Exception in Repeat Control Period: If one of the following instructions is executed at the address following RptDtct1, a general illegal instruction exception occurs. For details on an address to be saved in the SPC, refer to the description in section 4.4.3, Exception in Repeat Control Period. • Branch instructions BRA, BSR, BT, BF, BT/S, BF/S, BSRF, RTS, BRAF, RTE, JSR, JMP, TRAPA • Repeat control instructions SETRC, LDRS, LDRE • Load instructions for SR, RS, and RE LDC Rn,SR, LDC @Rn+,SR, LDC Rn,RE, LDC @Rn+,RE, LDC Rn,RS, LDC @Rn+,Rs |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |