Back Button ADP5501 Datasheet HTML 17Page - Analog Devices ADP5501 Datasheet HTML 18Page - Analog Devices ADP5501 Datasheet HTML 19Page - Analog Devices ADP5501 Datasheet HTML 20Page - Analog Devices ADP5501 Datasheet HTML 21Page - Analog Devices ADP5501 Datasheet HTML 22Page - Analog Devices ADP5501 Datasheet HTML 23Page - Analog Devices ADP5501 Datasheet HTML 24Page - Analog Devices ADP5501 Datasheet HTML 25Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 28 page
background image
ADP5501
Rev. 0 | Page 21 of 28
Bit
Name
R/W
Description
3
BL_AUTO_AD
J
R/W
0 = ambient light sensor comparators have no effect on the backlight operating level. The user can
manually adjust the backlight operating level using the BL_LVL bits.
1 = ambient light sensor comparators automatically adjust the backlight operating level. The internal
state machine takes control of the BL_LVL bits.
2
OVP_EN
R/W
0 = soft OVP protection disabled.
1 = soft OVP protection enabled.
1
FOVR
R/W
0 = backlight fade override is disabled.
1 = backlight fade override is enabled.
0
Not used
Table 10. Register 0x03, Backlight Off and Dim Timers (BL_TIME)
Bit
Name
R/W
Description
7 to 4
BL_OFFT
R/W
Backlight off timer; the timer should be set before BL_EN is set.
0000 = the timer is disabled.
0001 = 10 sec.
0010 = 15 sec.
0011 = 20 sec.
0100 = 25 sec.
0101 = 30 sec.
0110 = 35 sec.
0111 = 40 sec.
1000 = 50 sec.
1001 = 60 sec.
1010 = 70 sec.
1011 = 80 sec.
1100 = 90 sec.
1101 = 100 sec.
1110 = 110 sec.
1111 = 120 sec.
3 to 0
BL_DIMT
R/W
Backlight dim timer; the timer should be set before BL_EN is set.
0000 = the timer is disabled.
0001 = 10 sec.
0010 = 15 sec.
0011 = 20 sec.
0100 = 25 sec.
0101 = 30 sec.
0110 = 35 sec.
0111 = 40 sec.
1000 = 50 sec.
1001 = 60 sec.
1010 = 70 sec.
1011 = 80 sec.
1100 = 90 sec.
1101 = 100 sec.
1110 = 110 sec.
1111 = 120 sec.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com