Back Button AS8228 Datasheet HTML 26Page - ams AG AS8228 Datasheet HTML 27Page - ams AG AS8228 Datasheet HTML 28Page - ams AG AS8228 Datasheet HTML 29Page - ams AG AS8228 Datasheet HTML 30Page - ams AG AS8228 Datasheet HTML 31Page - ams AG AS8228 Datasheet HTML 32Page - ams AG AS8228 Datasheet HTML 33Page - ams AG AS8228 Datasheet HTML 34Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 123 page
background image
Data Sheet AS8218 / AS8228
Revision 3.0, 31-May-06
Page 30 of 123
If the target meter constant is different from one of the selectable (mconst) meter constants defined above:
e.g. 1,000i/kWh (Target Pulse Rate)
The same formula
)
mconst
(
Rate
Pulse
LED
)
ref
(
PR
Ni
=
can be used, but Ni is calculated using the Target Pulse Rate:
Rate
Pulse
et
arg
T
)
ref
(
PR
Ni
=
(Important: Select a pulse rate which is close to mconst, for the Target Pulse Rate, so that the Pulse_lev stays
within reasonable limits.)
After this calibration the energy equivalent of 1 fast pulse (1i) is different!
Standard: internal pulse rate: 204,800i/klWh
[]
Ws
58
.
17
800
,
204
Ws
600
,
3
000
,
1
i
1
=
×
=
When a special pulse rate is required, the following formula applies:
[]
Ws
e
etPulseRat
arg
T
PulseRate
LED
800
,
204
600
,
3
000
,
1
i
1
×
×
=
Example:
Assuming a pulse rate of 1,000 is required:
1,600
→ 204,800
1,000
→ 204,800 x 1,000/1,600
[ ]
Ws
13
.
28
600
,
1
/
000
,
1
800
,
204
Ws
600
,
3
000
,
1
i
1
=
×
×
=
Mains Current Leads/Lags Mains Voltage
The i_lead flag in the SREG/Status register determines if the mains current leads the mains voltage or lags the
mains voltage. The data is provided for reactive power calculation, to establish if the measured power is
capacitive or inductive.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com