132 / 330 page ![]() WM8351 Production Data w PD, April 2012, Rev 4.5 132 ADDRESS BIT LABEL DEFAULT DESCRIPTION R183 (B7h) DC-DC2 Control 12 DC2_HIB_MO DE 0 DC-DC2 Hibernate behaviour: 0 = Continue as in Active state 1 = Disable converter output 9:8 DC2_HIB_TRI G [1:0] 00 DC-DC2 Hibernate signal select 00 = HIBERNATE register bit 01 = L_PWR1 10 = L_PWR2 11 = L_PWR3 Note that Hibernate is also selected when a GPIO Hibernate input is asserted. Table 78 Hibernate Mode Control for DC-DC Converter 2 14.6.5 INTERRUPTS AND FAULT PROTECTION Each DC-DC Converter is monitored for voltage accuracy and fault conditions. An undervoltage condition is set if the voltage falls below 95% of the required level. The action taken in response to a fault condition can be set independently for each DC-DC Converter, as described in Table 79. The DCn_ERRACT fields configure the fault response to disable the respective converter or to shut down the entire system if desired. In addition, DC-DC Converter fault conditions also generate a second-level interrupt (see Section 24). To prevent false alarms during short current surges, faults are only signalled if the fault condition persists. When a DC-DC Converter is started up, any initial fault condition is ignored until the Converter has been allowed time to settle. The time for which any fault condition is ignored is set by the PUTO register field, as described in Table 79. ADDRESS BIT LABEL DEFAULT DESCRIPTION R181 (B5h) for DC-DC1 R184 (B8h) for DC-DC2 R187 (BBh) for DC-DC3 R190 (BEh) for DC-DC4 15:14 DCn_ERRAC T [1:0] 00 Action to take on DC-DCn fault (as well as generating an interrupt): 00 = ignore 01 = shut down converter 10 = shut down system 11 = reserved (shut down system) R177 (B1h) DCDC Active options 13:12 PUTO [1:0] 00 Power up time out value for all converters 00 = 0.5ms 01 = 2ms 10 = 32ms 11 = 256ms Note: n is a number between 1 and 4 that identifies the individual DC-DC converter Table 79 Fault Responses for DC-DC Converters |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |