79 / 518 page ![]() FALC ®56 PEF 2256 H/E Functional Description E1 User’s Manual 79 DS1.1, 2003-10-23 Hardware Description Figure 23 Automatic Handling of Errored Signaling Units Reset Counter values C s := 0 su := 0 [CMDR2.RSUC = 1] Idle in service SU in error? C s := Cs + 1 su := su + 1 su := su + 1 C s = T ? su = 256 ? su := 0 C s = 0 ? C s := Cs -1 in service Link failure [ISR1.SUEX = 1] Idle Notes: su: signaling units counter C s: errored signaling units counter T: error threshold (64 or 32), selectable by CCR5.SUET N N N N Y Y Y Y F0071 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|